System Setup
3-11
Part 1604858-01
E
2013 Nordson Corporation
Entering Configuration Mode
To enter configuration mode, press and hold the Plus and Minus buttons
simultaneously on the kV/uA panel, then either turn on power, or if the
controller is disabled press the Enable/Disable button. After 1 second all
panels will flash
CF
for 3 seconds. After 3 seconds the kV/
μ
A panel displays
F
−
1
for function 1. The controller is now in configuration mode.
To save your settings and exit configuration Mode, press the
Enable/Disable
button.
Atomizing Air
(Classic)
Total Flow
(Smart Flow)
Smart Coat Settings
KV/
μ
A Panel
KV/uA Selection
Smart Flow
Mode Indicator
Flow Air
(Classic)
Powder Flow Rate
(Smart Flow)
Enable/Disable
Trigger LED
Figure 3-10 Controller Interface
Function Settings
To change functions press the
+
or
−
buttons on the kV/
μ
A panel.
To change function settings press the
+
or
−
buttons on the Flow Air panel.
Function No.
Name
Settings
Default
1
Gun Type
0 = Encore
0
2
Trigger Type
0 = External, 1 = Continuous
0
3
Electrostatic Control
0 = Custom, 1 = Classic, 2 = PE
0
4
Powder Flow Control
0 = Smart, 1 = Classic
0
5
Cable Length
0 = 8 meters, 1 = 12 meters, 2 = 16 meters
0
NOTE:
Refer to the Operation section for explanations of the Electrostatic
Control and Powder Flow Control modes.
Summary of Contents for Encore LT Automatic
Page 4: ...Change Record ii Part 1604858 01 E 2013 Nordson Corporation...
Page 8: ...Table of Contents vi Part 1604858 01 E 2013 Nordson Corporation...
Page 12: ...Safety 1 4 Part 1604858 01 E 2013 Nordson Corporation...
Page 20: ...Description 2 8 Part 1604858 01 E 2013 Nordson Corporation...
Page 34: ...System Setup 3 14 Part 1604858 01 E 2013 Nordson Corporation...
Page 44: ...Operation 4 10 Part 1604858 01 E 2013 Nordson Corporation...
Page 63: ...Wiring Diagrams 7 1 Part 1604858 01 E 2013 Nordson Corporation Section 7 Wiring Diagrams...
Page 64: ...Wiring Diagrams 7 2 Part 1604858 01 E 2013 Nordson Corporation...