Installation
3-3
Part 104373
−
03
E
2015 Nordson Corporation
3
2
5
1
4
7
2
3
6
1
Siphon Connection
Pressure Feed Connection
Siphon Rod and Pressure Feed Connections
1. Siphon manifold
2. Siphon hose
3. Male connector
4. Siphon rod
5. Siphon strainer
6. Pressure feed line
7. Shutoff valve
Optional Circulation Kit Installation
Figure 3-3 shows a typical dual circulation installation for circulating
systems, using one of the circulation valve kits listed on page 7-5.
Items
2
−
5 are included in the kits, along with the required fittings.
Two
circulation kits are required for a dual installation.
1. Remove the pipe plugs at each end of the siphon manifold (1). Connect
the
1
/
2
-in. NPT circulation valves (2) to these ports.
2. Connect the drain valves (3), drain hoses (4) and drain rods (5) to the
circulation valves.
1
2
3
5
4
Figure 3-3
Dual Circulation Valve Installation
1. Siphon manifold
2. Circulation valves
3. Drain valves
4. Drain hoses
5. Drain rods