Installation
3-1
Part 104373
−
03
E
2015 Nordson Corporation
Section 3
Installation
WARNING:
Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
Suitable for installation in Zone 1, Zone 2, or normal usage areas.
Mounting and Grounding
1. Mounting slots are provided in the upper and lower heads. Install the
pump in an area accessible for operation and maintenance. Use four
hex head
1
/
2
-in. bolts to mount the pump to the wall or to a vertical
stand. See Figure 3-1 for mounting slot pattern.
WARNING:
To prevent static electricity build-up, ground the pump, all
system components, and the waste container. Ungrounded components
could cause a fire or explosion.
2. Connect the pump to a true earth ground, using the ground strap and
clamp provided.
(16.75 in.)
AIR MOTOR
UPPER HEAD
AIR MOTOR
LOWER HEAD
FLOOR
(57 in.)
1450 mm
(4.75 in.)
120.6 mm
425.5 mm
Figure 3-1
Mounting Slot Pattern