Installation
3-3
Part 7135457- E
E
2017 Nordson Corporation
Booth Conditioning Procedure
1. Remove any installation materials inside the booth.
2. Switch on booth extraction system by pressing
Fan start
on the booth
control panel.
3. Switch off
Recycle mode
on the booth control panel. the
Recycle system
operates in the spray to waste mode.
4. With all doors closed, use the blow lance to blow internal booth faces
free of dust.
5. Dampen a sponge with water and wipe clean internal booth faces,
Apogee
floor and internal cyclone access area. A drop of detergent
may be used for the first wash. Repeat the wash with water only.
6. Whilst allowing the booth to dry, wipe the exterior of the booth. The blow
lance may be used to decrease the drying time.
CAUTION:
Use a sharp solvent (see reference below) and apply to the
internal parts of the booth, base deflector and internal cyclone access area
with clean lint free wipers.
S
Use eye protection, mask and gloves
S
Polish dry
S
Wipe one square metre and blow with air lance and proceed until
complete
S
It is important not to touch the faces wiped with bare hands.
7. Allow to dry.
8. Spray powder to waste for 5 minutes, solvent clean any areas which
preferentially collect powder.
9. Clean cyclone and recycle in the normal way.
10. The system is now ready for use.