Troubleshooting
6-9
E
1996 Nordson Corporation
All rights reserved
107 041A
Issued 1/96
Manual 12-28
Problem
Possible Cause
Corrective Action
3. Conveyor speed never
stabilizes
Incorrect CPU card dip switch
settings
Refer to Table 6-6. Turn off oven and
remove CPU card from card cage.
Verify the settings on switches 6, 7, and
8 of Bank 2. Set switches as necessary.
Open or shorted cable 2455
If switch settings are correct, check
cable 2455 for an intermittent short or
open:
230PL–1 pin A7 to 241PL–1 pin 8
230PL–1 pin A8 to 241PL–1 pin 6
230PL–1 pin A9 to 241PL–1pin 9
If a short or an open is found, repair the
cable.
Bad dual-motor controller card
If a short or open is not found in cable
2455, replace dual-motor controller card.
Conveyor Speed Control
Problems
(contd)