![Nordmann AT4 D Series Mounting Instructions Download Page 24](http://html1.mh-extra.com/html/nordmann/at4-d-series/at4-d-series_mounting-instructions_1703694024.webp)
24
5.3.2
Mounting the steam generator
a
b
b
c
BB
A
A
Dimension
Unit type
522, 524,
532, 534,
822, 824,
832, 834
1532, 1534,
2362, 2364
3262, 3264,
4564, 6564
a
204,0 mm
205.0 mm
205.0 mm
b
40,0 mm
50.0 mm
52.5 mm
c
150,0 mm
210.0 mm
260.0 mm
Procedure
1. Mark the attachment points “A” for the wall support at the desired position
with the help of a spirit level. Then, drill holes diameter: 8 mm, depth:
40 mm.
2. Insert the supplied plastic plugs, and fix the wall support to the wall with
the screws supplied. Before tightening the screws adjust wall support
horizontally using a spirit level.
3. Unlock the screw of the front panel (steam side), then remove the front
panel.
4. Unmount the steam cylinder (see Nordmann AT4 D operating instruc
tions chapter 6.3.1).
5. Hang up the unit onto the wall support. Then, fix the unit to the wall
support using the supplied screws “B”.
6. Remount the steam cylinder (see Nordmann AT4 D operating instruc
tions chapter 6.3.1).
7. Reattach the front panel and secure it with the screw.
Summary of Contents for AT4 D Series
Page 2: ......
Page 50: ...Notes...
Page 51: ...Nordmann Engineering Ltd Printed in Switzerland Technical modifications reserved...