16
3.4.2.2 MultiPipe steam distribution system
The
MultiPipe
steam distribution system is used in ventilation ducts with a short humidification distance
(for the calculation of the humidification distance refer to
). When ordering an
MultiPipe
system the duct dimension must be specified. Please consult the data in the following table:
System 1
System 2
Number of steam connectors
1
2
Max. steam capacity
45 (30) kg/h
90 (60) kg/h
Duct width (B)
450...2700 mm
Duct height (H)
450...1650 mm
450...2200 mm
* For duct widths <600 mm the value in brackets apply
Note: further information on the MultiPipe steam distribution system can be found in the separate manual
supplied with the MultiPipe steam distribution system.
3.4.2.3 Fan unit FAN4 N ..
The fan units FAN4 N.. – in combination with the steam humidifiers Nordmann Omega Pro – are used
for direct room humidification. The fan units are mounted separately above the humidifiers to the wall.
Note: further information on the fan unit can be found in the separate manual supplied with the fan unit.
H
B
H
B