Industrial gear units – Operating and Assembly Instructions
46
B 1050 en-4419
Legend
1: Fusible plug
2: Mechanical switch
Figure 18: Fusible plug with separate mechanical switch
The triggering temperature of the fusible plug is usually 120°C. This ensures that the system is shut
down before the temperature for the fusible plug is reached.
The alignment of the mechanical switch must be checked with the aid of the manufacturer's
documentation prior to commissioning.
The switch must be connected to the evaluation electronics by the operator.
Information
As standard, turbo couplings are usually supplied filled with oil.
3.15.3 Dog coupling
Dog couplings require lubrication with grease to ensure wear-free function: Dog couplings must be re-
greased according to the manufacturer's documentation prior to commissioning.
Summary of Contents for B 1050
Page 1: ...B 1050 en Industrial gear units Operating and Assembly Instructions...
Page 2: ...Industrial gear units Operating and Assembly Instructions 2 B 1050 en 4419...
Page 6: ...Industrial gear units Operating and Assembly Instructions 6 B 1050 en 4419...
Page 83: ...7 Appendix B 1050 en 4419 83 Gear units SK 5207 SK 10507 M1 oil screw holes...
Page 85: ...7 Appendix B 1050 en 4419 85 Gear units SK 5207 SK 10507 M3 oil screw holes...
Page 87: ...7 Appendix B 1050 en 4419 87 Gear units SK 5207 SK 10507 M5 oil screw holes...
Page 89: ...7 Appendix B 1050 en 4419 89 Gear units SK 11207 SK 15507 M1 oil screw holes...
Page 91: ...7 Appendix B 1050 en 4419 91 Gear units SK 11207 SK 15507 M3 oil screw holes...
Page 93: ...7 Appendix B 1050 en 4419 93 Gear units SK 11207 SK 15507 M5 oil screw holes...
Page 95: ...7 Appendix B 1050 en 4419 95 Gear units SK 5217 SK 11217 M1 oil screw holes...
Page 97: ...7 Appendix B 1050 en 4419 97 Gear units SK 5217 SK 11217 M5 oil screw holes...
Page 112: ...6052902 4419...