On IEC B14 motors, all four fastening screws must be screwed into the flanged bearing plate even if
they are not required. The maximum insertion depth of 2 x d must not be exceeded. The fastening
screw threads must be inserted with a sealant, e.g. Loctite 242.
3.6 Subsequent painting
For retrospective painting of the drive, the radial shaft seals, rubber elements, vent screws, hoses,
name plates, adhesive labels and motor coupling components must not come into contact with paints,