7.1 General data for variable frequency drive
Function
Specification
Output frequency
0.0 … 400.0 Hz
Pulse frequency
3.0 … 16.0 kHz, factory setting = 6 kHz
Power reduction > 8 kHz with 115 / 230 V device, > 6 kHz with 400 V device
Typical overload capacity
150% for 60 s, 200% for 3.5 s
Efficiency
> 95% according to size
Insulation resistance
> 5 MΩ
Operating/ambient temperature
-25°C … +40°C, for detailed information (among others UL-values) about
individual device models and operating modes, please see (chapter
Fehler!
Verweisquelle konnte nicht gefunden werden.
).
ATEX: -20…+40°C (chapter 2.4)
Storage and transport temperature
-25°C … +60/70°C
Long-term storage
(chapter 9.1)
Degree of protection
IP55, optional IP66 (chapter 1.8)
NEMA1, higher NEMA classifications upon request
Max. installation altitude above sea
level
Up to 1000 m
No power reduction
1000
m...2000 m:
1 % / 100 m power reduction, overvoltage category 3
2000
m...4000 m:
1%/100 m power reduction, overvoltage category 2, external
overvoltage protection required at power input
Ambient conditions
Transport (IEC 60721-3-2):
Mechanical: 2M2
Operation (IEC 60721-3-3):
Mechanical: 3M7, 3M6 (size 4)
Climatic: 3K3 (IP55)
3K4 (IP66)
Environmental protection
Energy-saving function
(chapter
Fehler! Verweisquelle konnte nicht
gefunden werden.
), see P219
EMC
(chapter
Fehler! Verweisquelle konnte nicht
gefunden werden.
)
RoHS
(chapter 1.5)
Protective measures against
Overtemperature of the variable frequency drive
Overvoltage and undervoltage
Short circuit, ground fault,
overload, idle running
Motor temperature monitoring
I
2
t motor, PTC/bimetallic switch
Regulation and control
Sensorless current vector control (ISD), linear V/f characteristic, VFC open-loop,
CFC open-loop, CFC closed-loop
Waiting time between two power-up
cycles
60 s for all devices in normal operating cycle
Interfaces
Standard
RS485 (USS) (for parameterization units only)
RS232 (Single Slave)
System bus
Optional
AS-i on board (chapter
Fehler! Verweisquelle
konnte nicht gefunden werden.
)
Various bus modules (chapter 1.2)
Electrical isolation
Control terminals
Connecting terminals, electrical
connection
Power unit
(chapter 2.3.2)
Control unit
(chapter 2.3.3)
Pos: 731 /Anleitungen/El ektr onik/FU und Starter/8. Z usatzi nform ati onen/!Z usatzi nformati onen (Überschrift) [SK 1xxE, SK 2xxE, SK xxxE-FD S] @ 0\mod_1328183966749_14638.docx @ 15181 @ 1 @ 1
Summary of Contents for NORDAC FLEX SK 205E Series
Page 1: ...BU 0240 en US NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters...
Page 4: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 4 BU 0240 en US 4920...
Page 29: ...2 Mounting and installation BU 0240 en US 4920 29 Installation Size 1 3 Size 4...
Page 97: ...Key word index BU 0240 en US 4920 97...
Page 98: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 98 BU 0240 en US 4920...
Page 99: ...Key word index BU 0240 en US 4920 99...
Page 100: ...6072403 4920...