Norbec Intelligence I3 Operating Instructions Download Page 1

 

 

 

 

 

 

 

 

 

1.

 

Panic Alarm Buzzer 

2.

 

Battery (9 Volt) Holder 

3.

 

Display 

4.

 

High Temp alarm Button 

5.

 

Light Switch Button 

6.

 

Set Button 

7.

 

Low Temp Alarm Button 

8.

 

Up Button (and Mute) 

9.

 

Down Button 

10.

 

Mute Button (only mute the loud Buzzer) 

 

DESCRIPTION FOR EACH FEATURE   

Activation & disabling the module 

Before being delivered to the customer, the module is disabled. 
The  ''OFF''  message  is  displayed  on  the  screen.  When  the 
module is disabled, only the alarms and temperature displays 
are  deactivated.  It  is  always  possible  to  control  the  lighting 
manually  or  automatically,  with  the  door  (See  ''lighting 
Control'').  Note  that  all  the  initial  parameters  and  those 
modified  by  the  customer  are  stored  in  memory  when  the 
module is disabled. 
 
Refer  to  ''keypad  Operation''  section  on  how  to  enable  and 
disable the module.  
 

Temperature monitoring and display 

The  unit  displays  the  temperature  in  degrees  Celsius.  Should 
one  or  more  alarms  be  present,  the  display  will  show  the 
temperature and the alarm message(s) alternatively. 
 

Lighting control 

The lighting is controlled two different ways;

 

1.

 

By  pressing  the  button  on  the  keypad,  which  will  switch 
alternatively ON and OFF. 

2.

 

By detecting the opening of the door,  which will turn the 
lights  ON  and  the  closing  door  will  initiate  a  5-minute 
countdown. The light will then go OFF after this delay.  

Temperature Alarms 

These alarms are activated 45 minutes (adjustable, see 

«parameter descriptions» after reaching the 
temperature alarm settings. An audible alarm (about 55 
dB) from the keypad will then occur. The display will 
show the message HA (High Temp Alarm) Or LA *Low 
Temp Alarm), alternatively with the actual temperature. 
The 115 Volt alarm signal will turn ON.

 

 
The  High  and  Low  temperature  alarm  setting  and  the 
activation delay can be modified in the parameters menu. 

 
Door Open Alarm 

If  the  door  remains  open  for  more  than  15  minutes 
(adjustable, see 

« parameter descriptions»), this alarm is 

triggered  and  an  audible  alarm  from  the  keypad  will 
occur. The display will show the message dA (Door Open 
Alarm),  alternatively  with  the  actual  temperature.  The 
115 Volt alarm signal will turn ON.

 

OPERATING AND CONFIGURING INSTRUCTIONS

 