norbar NORTRONIC Operator'S Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

OPERATOR’S MANUAL 

NORTRONIC

®

 

Part Number 34399 | Issue 4 | Original Instructions (English) 

 

NORBAR TORQUE TOOLS LTD 

Wildmere Road, Banbury, 
Oxfordshire, OX16 1JU 
UNITED KINGDOM 
Tel + 44 (0)1295 270333 
Email [email protected]  

 

 

 

NORBAR TORQUE TOOLS PTY LTD 

45–47 Raglan Avenue, Edwardstown, 

SA 5039 

AUSTRALIA 

Tel + 61 (0)8 8292 9777 

Email [email protected] 

 

 

 

NORBAR TORQUE TOOLS INC 

36400 Biltmore Place, Willoughby, 

Ohio, 44094 

USA 

Tel + 1 866 667 2279 

Email [email protected] 

 

 

 

 

 

 

 

 

NORBAR TORQUE TOOLS PTE LTD 

194 Pandan Loop 
#07-20 Pantech Business Hub 
SINGAPORE 128383 
Tel + 65 6841 1371 
Email [email protected] 

 

 

 

NORBAR TORQUE TOOLS (SHANGHAI) LTD 

91 Building-7F, No.1122 North Qinzhou Rd, 

Xuhui District, Shanghai 

CHINA 201103 

Tel + 86 21 6145 0368 

Email [email protected] 

 

 

 

NORBAR TORQUE TOOLS INDIA PVT. LTD 

Plot No A-168, Khairne Industrial Area, 

Thane Belapur Road, Mahape, 

Navi Mumbai – 400 709 

INDIA 

Tel + 91 22 2778 8480 

Email [email protected] 

 

 

www.norbar.com 

 

 

 

© Norbar Torque Tools Ltd 2018 

www.norbar.com/HowtoUseANorTronic 

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for NORTRONIC

Page 1: ...OPERATOR S MANUAL NORTRONIC Part Number 34399 Issue 4 Original Instructions English All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...All manuals and user guides at all guides com...

Page 3: ...play Offset 9 of Saved Readings 9 Sleep 9 Resume from Sleep Gyroscope drift calibration 9 USB Interface 10 Wireless Interface 11 Low Battery 11 Flat Battery 11 Torque CRS 11 Multiplier 11 Exit Measure...

Page 4: ...ts 23 Erase All 23 About 24 Specifications 25 EU Declaration of Conformity 27 Maintenance 28 NorTronic Calibration 28 Battery Replacement 28 Repair 28 Cleaning 28 Product Disposal 28 Battery Disposal...

Page 5: ...915 MHz 43505 50 N m 915 MHz 43506 200 N m 915 MHz 43507 330 N m 915 MHz NorTronic models 43500 43501 43502 43503 use an 868MHz wireless frequency this is designed for use in Europe NorTronic models 4...

Page 6: ...Operational from three AA internal rechargeable non rechargeable batteries Up to 15 linked or non linked Targets can be on the tool at any one time USB port for interface to TDS Built in Wireless tra...

Page 7: ...OISTURE BEFORE USE Battery Fitting Replacement NOTE Insert positive battery terminal into handle cavity first Rotate the end cap clockwise to tighten and counter clockwise to release Ratchet Head Fitt...

Page 8: ...l Capacity ISO6789 2017 7 Current Torque Units 8 Torque reading 9 Angle reading 10 Current Snug Torque Angle Target 11 Torque CRS has been changed from default value 12 Multiplier in use 13 Audit Targ...

Page 9: ...tting for the tool If the Snug Torque value is set See page 13 and is above the Active From setting the Angle display is shown as 0 until the Torque reaches the Snug Torque value and then displays the...

Page 10: ...e saved to the Data Store on the NorTronic If a Target is in use and a reading has been saved press the UP button and hold in for 2 seconds to delete the last reading that has been saved via the Delet...

Page 11: ...when the Tool Target has been changed Sleep The NorTronic will Sleep if any of the events listed below have not happened during the time period specified in Tool SETUP Sleep see page 19 for more info...

Page 12: ...ith TDS installed using the cable supplied NOTE Remove the USB cover to access the USB connector The USB cover must be fitted for IP44 protection Test Results saved on the NorTronic to the Data Store...

Page 13: ...eless or USB icons but the NorTronic will remain connected Flat Battery The Flat Battery icon will be shown for approximately 30 seconds before shutting down Further button presses will not wake up th...

Page 14: ...the Wireless interface is used the Wireless icon will change from to when the tool is connected to Receive Results in TDS After a peak has been detected press ZERO to send both the peak Torque Angle...

Page 15: ...ither Set Angle Limit or Set Angle The button is not functional go to Set Angle Limit go to Set Angle Set Angle Limit NOTE This screen will only be shown if was selected on the Audit mode screen Set A...

Page 16: ...Torque Angle Target if it is set to a value above the Torque Target setting the Final Target is enabled Torque Angle with Final Torque Target Linked Targets Linked Targets can only be set up in TDS T...

Page 17: ...n the tool unless the Locked option has been ticked in Set Tool Options and downloaded to the NorTronic by clicking the Update button on Set Tool Options as shown below See page 16 for more informatio...

Page 18: ...Angle Display Auto Zero Active From Vibrate Wireless Auto Reset Inverse Display Torque Centres and Multiplier NOTE Tool SETUP is active unless the Lock option has been ticked and downloaded to NorTron...

Page 19: ...PLAY MULTIPLIER COMPLETE WARNINGS TORQUE CRS Torque Limits Torque HI Limit 4 LO Limit 4 Press or to change highlighted value Press to confirm and go to LO Limit Press to exit to SETUP saving changes o...

Page 20: ...ighted to go to 2nd units screen shown below Units lbf ft in lb lbf in ozf in ft lb in oz Press or to highlight unit Press to select Unit and Exit Press to exit to SETUP no changes Minimum Enabled 1 M...

Page 21: ...g Press or to confirm and exit to SETUP Display Torque Angle Display Torque only Auto Zero Auto Zero Press or to change setting Press or to confirm and exit to SETUP both the TORQUE ANGLE readings wil...

Page 22: ...MHz Press or to change value Press to confirm and go to SETUP saving changes Press to confirm and exit to SETUP saving changes A Node number is an individual identification of a tool on the wireless...

Page 23: ...ime 4Sec Press or to change value Press or to confirm and go to SETUP saving changes Minimum 1 Maximum 10 Default 4 Display Inverse Press or to change setting Press or to confirm and go to SETUP savin...

Page 24: ...Warnings Screen on power up or resume from sleep if the Multiplier or Torque CRS settings are not default Do not show the Warnings Screen on power up or resume from sleep if the Multiplier or Torque...

Page 25: ...or buttons to scroll through the Saved Test Results screen s Press the button to exit back to Data Store Result 30 03 12 10 48 23 360 5 N m 101 Erase All Delete Results Y N Press or to change highlig...

Page 26: ...n if the Multiplier Torque CRS or both have been changed from their default values Tool Identification Serial 2017 123456 Part 43502 Version Capacity Version 2 XX Capacity 200 N m Hardware options fit...

Page 27: ...34 hours continuous 136 hours with a 25 duty ratio 17 x 8 hour shift Dependant on display settings Power consumption 130 mW maximum Batteries AA 2500 mAh 1 2 volt NiMH Nickel metal Hydride Coin cell R...

Page 28: ...terference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment OFF and ON th...

Page 29: ...RED Directive 2014 30 EU on Electromagnetic Compatibility EMC Directive 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous subst...

Page 30: ...ved agent where all the facilities to ensure the NorTronic is functioning at maximum accuracy are available Cleaning Do not use abrasives or solvent based cleaners Product Disposal This symbol on the...

Page 31: ...ter when approaching a Target Apply the torque slower GLOSSARY OF TERMS Word or Term Meaning Number Active From Value from which the memory modes operate Capacity NorTronic full scale CRS Centres Freq...

Page 32: ...R TORQUE TOOLS PTE LTD 194 Pandan Loop 07 20 Pantech Business Hub SINGAPORE 128383 Tel 65 6841 1371 Email enquiries norbar sg NORBAR TORQUE TOOLS SHANGHAI LTD 91 Building 7F No 1122 North Qinzhou Rd X...