3-axis magnetometer device suitable for compass application
•
Built-in A to D converter for magnetometer data out
•
Self test function
•
I2C bus interface
•
Power modes: OFF mode, stand-by mode and active mode
•
DRDY function for measurement data ready
•
INT function to inform exceeding magnetic field strength threshold.
The operating temperature is -20°C to +85°C.
The operating supply voltages are:
•
Analogue 2.4V to +3.6V
•
Digital interface 1.70V to analogue supply voltage.
Figure 60 Magnetometer
Audio concept
Audio HW architecture
TPA6140 (N2000), BoostMono (N2150) along with mixed-signal ASIC Gazoo/Pearl provides the analogue audio
output interfaces and RAPU provides the digital audio output interface support.