Figure 95 State diagram
Voltage limits
Parameter
Description
Value
VMSTR
Master reset threshold (RETU)
2.2V (typ.)
VMSTR+
Threshold for charging, rising
(TAHVO)
2.1V (typ.)
VMSTR-
Threshold for charging, falling
(TAHVO)
1.9V (typ.)
VCOFF+
Hardware cutoff (rising)
2.9V (typ.)
VCOFF-
Hardware cutoff (falling)
2.6V (typ.)
SWCOFF
SW cutoff limit
~3.2V
RM-57/58
System Module
Nokia Customer Care
Issue 1
Company Confidential
Page 9–11
Copyright ©2005 Nokia. All Rights Reserved.
Summary of Contents for RM-57
Page 391: ...www s manuals com ...