52/113
8.1.2 T Select tone dialling
Command
execute
T
Mandatory. V.25ter section 6.3.2. This setting is ignored.
8.1.3 P Select pulse dialling
Command
execute
P
Mandatory. V.25ter section 6.3.3. This setting is ignored.
8.1.4 A Answer
Command
Possible
verbose
result codes (
V1
)
Numeric
(
V0
)
Description
execute
A
CONNECT
1
data/fax call established; rate 300 bps (or
X
forbids rate display)
or GPRS context activation
CONNECT 1200
5
data/fax call established; rate 1200 bps
CONNECT 2400
10
data/fax call established; rate 2400 bps
CONNECT 4800
11
data/fax call established; rate 4800 bps
CONNECT 9600
12
data/fax call established; rate 9600 bps
CONNECT 14400
17
HSCSD (or 14.4 tch) data/fax call established; rate 14400 bps
CONNECT 19200
18
HSCSD data/fax call established; rate 19200 bps
CONNECT 28800
19
HSCSD data/fax call established; rate 28800 bps
CONNECT 38400
20
HSCSD data/fax call established; rate 38400 bps
CONNECT 43200
21
HSCSD data/fax call established; rate 43200 bps
ERROR
4
command cannot be actioned
NO CARRIER
3
call could not be established
OK
0
command aborted
Mandatory. V.25ter section 6.3.5. All result codes are not in V.25ter. Before one of the above
codes is issued, the terminal may return some of the following codes:
+CR
,
+ER
,
+DR
, or
+ILRR
(in that order). In GPRS connections the data rate can actually be higher than the
value returned because it is the minimum desired value. The only verbose code returned in
the case of a GPRS call is the word CONNECT.
8.1.5 H Hook control
Command
Description
execute
H[0]
Hang up all calls (except possible waiting call) if only single mode calls in
progress.
Mandatory. V.25ter section 6.3.6.