Operating mode
Stand alone
Associated digital set
To configure the AP Interface Module, open the device with the 2 screws, located under the module.
If the jumper is positioned for "stand-alone" operation, an associated set cannot work.
If the jumper is positioned for "associated digital set" operation, an associated set is mandatory, the
Interface Module cannot work without it.
8.8.3 External connections
8.8.3.1 Connecting AP Interface Module
Fax or Modem
9 Series Set
AP Interface Module
Mains Power Supply
2
4
Wall Socket
(to PCX)
Analog Line
UA Line
UA Line
(optional)
1
3
Figure 8.12: AP Interface Module Connections
The AP Interface Module is connected to:
1.
Digital set ( RJ11/RJ11 cable). 3 m maximum length
2.
OXO Connect via a wall socket and a distributor frame.
Connect an AP module is identical to connect a digital set.
Maxinum length between AP module and PCX depends on cable quality. For example:
• LY 0.5 mm cable: up to 800 m
• Ref 278 0.6 mm cable: up to 1200 m
3.
Analog device with an RJ45 or RJ11 cable. 100 m maximum length
4.
Power supply unit (see details below)
Chapter
8
Device commissioning
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
148/216