In the case of 4135 IP Conference Phone sets, suboption 67 of option 43 provides the path of
configuration files on the ALE International.
The DHCP offer provides the following parameters:
• IP address
• Router IP address
• Subnet mask
• Option 66: IP address or name of the OXO Connect:10443, for example
192.168.12.34:10443
• Suboption 67 of option 43: the value of this sub-option must contain a string value set to
https://
alize/dmcfg/
• Option 58: VLAN ID: this is sent as a suboption of option 43
Optionally, the DHCP offer can include the following parameters, which can also be configured locally
on the terminal or on the OXO Connect:
• Option 6: Domain Name Server (DNS primary and secondary)
• Option 15: Domain name
• Option 12: Host name (eg, ICTouch<MAC>)
• Option 42: SNTP server
• Option 120: SIP server (outbound proxy server address or name)
Exporting the server certificate from the OXO Connect
1.
Go to
OMC->Import/Export->Export Server Certificate
.
The
Export Server Certificate
window is displayed
2.
Click
Browse
button.
The
Exportfile
window is displayed:
• The
File name
field indicates
server.crt
. The file name can be modified as needed
• The
Files of type
field indicates
Certificate Files
3.
Specify the destination path for the export and click
OK
: The selected path and the certificate file
name are displayed in the
Export Server Certificate
window
4.
Click the
Export
button: The certificate file is exported from the OXO Connect to the specified file
path in PC
5.
Click the
Return
button
Configuring network parameters for static initialization
The following parameters must be entered through the MMI:
•
IP address
•
Subnet mask
•
Gateway address
•
DNS addresses
•
VLAN use
•
VLAN ID
(if VLAN use is set)
•
URL:
provides the URL on the OXO Connect to download configuration file. The path on the OXO
Connect is
/dmcfg/
•
SIP password
8.1.3.1.2.5 Configuring the user name and password in OMC
To modify the name and password:
• In OMC, go to
Users/Base stations List
.
• Click the user in the list.
Chapter
8
Device commissioning
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual