Configure an E-240W-A indoor ONT
74
7368 ISAM ONT E-240W-A Product Guide
3FE-46974-AAAA-TCZZA
Issue: 01
Table 16
Optics module status parameters
2
Click Refresh to update the displayed information.
3
STOP. This procedure is complete.
Procedure 13
Statistics retrieval
1
Select Status > Statistics from the top-level menu in the EPON Home Gateway window.
Statistics are available for LAN ports, WAN ports, and WLAN ports.
shows the statistics for the LAN ports.
Field
Description
Laser Bias Current (ONT ANI-ONT-Side Optical
Measurements)
Laser bias current, measured in uA
Optics Module Voltage (ONT ANI-ONT-Side Optical
Measurements)
Optics module voltage, measured in V
Optics Module Temperature (ONT ANI-ONT-Side Optical
Measurements)
Optics module temperature, measured in C
Rx Optics Signal Level at 1490 nm (ONT ANI-ONT-Side
Optical Measurements)
Received optics signal level at 1490 nm,
measured in dBm
Tx Optics Signal Level at 1310 nm (ONT ANI-ONT-Side
Optical Measurements)
Transmitted optics signal level at 1310 nm,
measured in dBm
Release 06.00.00h | January 2019 | Edition 08