Table 8 Calibration value limits
Parameter
Min.
Max.
ADC Offset
-20
20
ADC Gain
12000
14000
BSI Gain
1100
1300
VBAT Offset
2400
2650
VBAT Gain
19000
23000
VCHAR Gain
N/A
N/A
IBAT (ICal) Gain
7750
12250