Results
Calibration data will be stored to the phone.
Next action
Continue to next band.
Compensating RX band filter response
Context
Rx band filter response compensation has 9 steps for each band.
Rx band filter response compensation requires an external signal generator.
Steps
1. Select Tuning -> RX Band Filter Response Compensation
Figure 132 RX band filter response compensation
i
Select Manual Tuning mode
ii Press Start.
iii Initial data will be loaded from the phone.
iv Press tune to start calibration.
v Follow the instructions given in the following pop–up window and set frequency and level of the signal
generator.