Page 1: ...ORTABLE TYPE AIR CONDITIONER USER MANUAL For Thank you for selecting our quality air conditioner Please be sure to read this user manual carefully before using Enquiries should be directed to Nobo on 1800 087 840 ...

Page 2: ... share the power supply outlet with other appliances Do not rest hot or heavy objects on the appliance Always unplug the unit from the power outlet before cleaning or maintenance operations for example filter cleaning Clean the filters at least once every two weeks Do not splash the unit with water Do not move the unit by pulling the exhaust hose attached to the back of the unit Do not move air co...

Page 3: ...TENTS Introduction 3 Installation 5 Control panel 9 Operation of control panel 9 Operation of remote control 11 Water drainage methods 13 Maintenance and service 14 Trouble shooting 16 2 NOBOCOOL NC 39BP C ...

Page 4: ...to cool large open areas Close all doors and windows in the room being cooled Do not place the air conditioner in direct sun light Close all curtains in the room being cooled For maximum cooling COOLING MODE set the temperature at 18 C and the fan at HIGH After In COOLING MODE once the existing room temperature reaches the set temperature the fan continues operating and the compressor switches on ...

Page 5: ...2 Up down manually adjusted air fins 3 Air outlet 4 Left Right auto air swinging fins 5 Rolling castor 6 Cable power cord and plug BACK Fig 2 1 Hot air outlet grill 2 Low air inlet grill 3 High air inlet grill 4 Power cord hooks 5 Water tank chassis 6 Water tank drain outlet 7 Plug NOBOCOOL NC 39BP C ...

Page 6: ...ortable air conditioner in a flat location where the air inlets and outlets cannot be covered up Place the unit no less than 50cm away from a wall or other obstacle INSTALLATION ACCESSORIES 5 5 0 c m 50cm Fig 3 user manual remote control batteries NOBOCOOL NC 39BP C ...

Page 7: ... window slider MOUNTING OF ASSEMBLED AIR EXHAUST HOSE Fig 5 Take care not to damage the hose inlet when attaching detaching at the back of the Air Conditioner Slide the hose inlet square end in the direction indicated by the arrow onto the fixing lugs on hot air outlet grill at the back of the appliance Install carefully and do not force Place the hose outlet to the nearest window The length of th...

Page 8: ...ulling the air exhaust hose attached to the back of the appliance Do not move the air conditioner when it is operating Correct exhaust hose mounting shown below If mounting in the wall the height of the hole should be 40cm 130cm Fig 6 If the air exhaust hose needs to be bent the correct method is shown below Fig 7 Incorrect or excessive bending of the exhaust hose will cause inefficient cooling an...

Page 9: ...y require the use of cardboard fillers and or duct tape to install Please refer to illustration for minimum and maximum window openings Insert Altitude unlimited drawing here awning window and sliding door Fig 11 and 12 8 Fig 9 Fig 10 Fig 11 Fig 12 Window slider length Min 85cm Max 123cm Gaps can be sealed using cardboard and duct tape Window Door slider height Max 123cm Standard door height 210cm...

Page 10: ...OLING mode OPERATION OF CONTROL PANEL The operating ranges for cooling and dehumidifying are 18 C 32 C If the appliance is turned off during cooling or dry operation and restarted immediately the unit will wait at least 3 minutes before restarting the compressor POWER SUPPLY Do not connect the portable air conditioner to a power supply outlet which is also being used for other electrical appliance...

Page 11: ... not need to be connected SETTING THE TIMER This timer can be used to delay the appliance start up or shutdown This avoids wasting electricity by optimizing operating periods PROGRAMMED SHUTDOWN With the appliance on press TIMER button the time remaining until shutdown is displayed on LCD Set the time when you want the appliance to switch off with INCREASE and DECREASE buttons from 30 minutes to 2...

Page 12: ...eiver Do not drop remote control expose it to direct sunlight or leave it near sources of heat COOL DRY FAN HIGH MED LOW SWING TIMER ON TIMER OFF MODE FAN SWING ON OFF TIMER AUTO TIMER selection MODE selection FAN speed selection temperature time display FAN speed button press this button to select fan speed of AUTO HIGH MED or LOW SWING button press this button to switch the automatic swing funct...

Page 13: ...ne hour intervals can be selected Press the TIMER button again to confirm the timer setting the TIMER INDICATOR LIGHT lights up and keeps flashing to indicate the timer is activated At the end of the set time the appliance switches off automatically To cancel the TIMER setting press the TIMER button again PROGRAMMED STARTUP Turn on the appliance and select the required mode for example Cooling mod...

Page 14: ...g the on off switch on the unit or remote control Then drain the water tank by unplugging the drain outlet and allowing the water to flow onto the drain pan The drain pan will not hold the full contents of the water tank A number of fills of the drain pan are required It may be easier after 3 or 4 pans have been drained in order to avoid accidental spillage when shifting the air conditioner to whe...

Page 15: ...an the surface of the unit with a damp cloth then dry with a duster or similar CLEANING THE AIR FILTER Clean the dust filter once every two weeks of operation This will keep the air conditioner working efficiently Slide out the air filter from the side as shown in Fig 21 Wash the air filter by immersing it gently into warm about 40 C or 104 F water with a dishwashing detergent Rinse the filter of ...

Page 16: ...and dispose of the water Tilt the unit by lifting it at the front to ensure all water is removed from the water tank Then operate the unit in fan mode for half a day until the pipe is dry Wind the cable around the cable hooks on the back of the appliance Wrap the appliance with the plastic bag and keep it in a dry place 15 Power cord hook Power cord Plug Fig 22 NOBOCOOL NC 39BP C ...

Page 17: ...mer setting by pressing Is compressor light illuminated Wait 3 minutes from turning on safety device prevents compressor which provides cooling being turned on for about 3 minutes TIMER button The compressor has stopped but the fan and water pump continue to operate Is Ft displayed on LCD Drain water Air Conditioner not cooling satisfactorily Has the temperature been set low enough Air exhaust hos...

Page 18: ... When the appliance is operating in dehumidifying mode this device prevents the formation of ice The appliance starts up again automatically when the defrosting process is complete PF PROBE FAILURE Sensor damaged If this is displayed contact Nobo on 1800 087 840 Ft FULL TANK The water tank is full Empty the internal tank see the section on Water Drainage Method 17 NOBOCOOL NC 39BP C ...