19
Buffer Water Tanks
1.
Connect the pipeline of the upper part of the collector to
the hydraulic unit (position Ι)
2.
Connect the pipeline of the domestic water heat
exchanger inlet to the hydraulic unit (position ΙΙ).
3.
Connect the pipeline of the collector’s bottom part to the
hydraulic unit (position ΙΙΙ).
4.
Connect the domestic water heat exchanger outlet to the
hydraulic position IV.
5.
Connect the expansion tank’s pipeline (to the position V).
6.
Connect the evacuation pipeline of the safety valve to the
position VI of the hydraulic unit.
NOTE:
The safety valve should have a drain pipe
connected to its outlet. This pipe should run to ground
level where hot water discharge is safe and clear of
any paved areas. Do not seal or block the ends of this
drain pipe or the valve outlet. Antifreeze solution may be
drained from this pipe during high irradiation situations.
7.
Connect sensor Nr. 13 (S1 FKP 6) to the collector’s
upper part.
8.
Connect sensor Nr. 14 (S2 FRΡ 6) to the lower coil
sensor position.
9.
Connect sensor Nr. 15 (S3 FRΡ 6) to the upper coil
sensor position.