background image

 

Non-Linear Systems 

 

PC-40

   

4-Digit

 

Up/Down Event 

Counter 

 

 

 

 

INTRODUCTION

 

The PC-40 Digital Panel Counter is a solid-

state, 4 digit, up/down event counter or 

totalizer. It is designed to provide totalizing 

capability from either contact closures or 

logic-level signals. The count, reset and 

latch inputs are conditioned to provide high 

noise immunity. It is a highly reliable 

component which can be used to replace 

electromechanical types.  

 

The PC-40 is designed to operate with a 

+5VDC  

±

5% power supply. See Figure 1 for 

a t5V power supply circuit for 

operation from 120VAC.  

 

Figure 1

.  Typical Power Supply 

 

SPECIFICATIONS 

COUNT RATE:

  

    

Logic Level: * 0 to 1,000,000/sec 

    Contact Closure:   0 to 50/sec 

*This speed is achieved by removal of internal capacitors which 

normally provide filtering of contact bounce

 

INPUT SIGNAL AMPLITUDE: 

 

Logic Level:  +3.0V to +15V 

  Contact Closure: Ground for count 

 

DISPLAY: 

 

0.3" high LED, 4 Digits 

 

OVERFLOW INDICATION:

  

     

Blinking Decimals (up only) 

 

POWER:

    

+5VDC 

±

5% @ 0.75W

 

 

OPERATING TEMP.:   

 

0

°

 to 50

°

C

 

 

WEIGHT:    

 

4oz (113 g) 

 

DECIMAL LOCATION:

 Positioned by 

jumper on connector to any one of 4 

locations. 

 

 

BCD OUTPUT:

 

Multiplexed, bit parallel 

character serial at approximately a 600 Hz 

rate.

 

 

DECIMAL POINT OUTPUT:

  

Multiplexed, pulse occurs on decimal point 

common at the same time as the pulse for 

the digit to the right of the decimal occurs. 

 

ZERO SUPPRESSION: 

Ground to 

inhibit 

 

BLANKING/DISPLAY INHIBIT: 

For on or 

off intensity  control, connect to +5VDC 

through a potentiometer (0-1K

) and switch 

(if desired) maximum current is 150mA. 

 

RESET:

 

Negative going to low (GND) from 

logic level source on switch closure to GND.

 

 

CARRY:

  

At 9999 count, an output is 

provided which goes positive (true). The 

output goes to zero (low) at the next pulse 

input to the counter. This occurs once each 

10,000 pulses at the input. Designed for use 

when cascading counters. 

 

LATCH  ENABLE:

  (

For counts to 9999) 

Open holds reading on counter at the time of 

opening. Ground returns display to count at 

the time of grounding (total since last reset). 

 

OPERATING PRINCIPLES

 

INPUT CIRCUIT:

 

The input circuit contains 

an amplifier-filter to permit a contact closure 

to be counted as a pulse input  even if 

contact bounce is present. If high speed 

operation (above 50 per second) is desired, 

up to 1,000,000 per second, internal filter 

capacitors must be removed. 

 

Figure 2.

    Simplified Block Diagram 

 

COUNTER:

 

The counter is a single 

integrated circuit which is capable of 

counting at a 1 MHz rate to a total of 9999. 

The counter provides a carry output for 

cascading counter for greater range. The 

counter can be reset by a logic-level signal 

or a contact-closure

 

LATCH: 

The latch is externally controlled to 

hold and display the total count when the 

latches are enabled. This count will

 

continue 

to be displayed until the latch

 

enable is 

removed. Release of the latch enable results 

in the latches and display being updated to 

the then total count on the counter. From the 

latch circuits, multiplexed BCD data is 

available for the four decimal digits and the 

decimal point. The multiplex rate is 

approximately 600 HZ. Four strobe lines are 

sequentially energized to tell which decimal 

digit is being output on the four BCD data 

lines. The sequence begins with the most  

 

 

 

significant digit and proceeds to the least 

significant digit. This sequence is repeated 

at a rate of approximately 150Hz. The data 

output is the same as that presented in the 

display. 

 

DISPLAY: 

 

The display may be used on or 

off as desired. Further, it permits control of 

the intensity of the display by using an 

external potentiometer. 

 

The leading zeros may be suppressed by 

means of a special input; the counter will not 

suppress to the decimal point selected.  At 

all zeros (0000), the display is blank. 

 

INSTALLATION

 

Mount the PC-40 as follows: 

 

1. Cut a hole in panel (figures 3 and 4). 

2. Slide trim plate over PC-40 housing, 

facing beveled edge of trim plate forward.    

3. Insert PC-40 through the cutout in the  

    panel from the front of the panel.

 

4. Fit mounting clips (2) into the slots at the   

    sides of the meter. The foot of the clip  

    should face forward. 

5. Thread the screws (2) into clips and    

    tighten the screws against the rear 

surface of the panel. 

 

      

 

 

 

Panel Cutout 

w /Trim Plate

Center Line 

w ithout Trim 

Plate

Center Line 

w /Trim Plate

Cutout For Multiple 

Mounting w ithout Trim 

Plate

A

2 17/32

B

31/32

C

15/16

1 3/16 min

D

3 1/8 min

3 1/8 min

E

Number of units x 15/16

 

Figure 3

.    Mounting Data 

 

Figure 4.

    Outline Drawing 

 