Setting Parameters
page 125
NF 650 - rev. 01 / 29.06.2020
35 Communication Parameter Menu
This menu is used to set up communication to other devices.
Furthermore the network integration can be set up here as well. The details will not be
explained here.
If you should not have the required IT skills we recommend you leave such tasks to
IT specia-
lists
or the
NIVUS commissioning personnel
.
Fig. 35-1
Communication
35.1 TCP/IP
Settings for data transport within a decentralised network. Here the settings for the IP address
and the domain are adjusted or only displayed.
• >IP automatic<:
if active (check box) the IP address is provided automatically via DHCP by the
network; the addresses are read-only parameters and cannot be changed manually; if
the function is active the DNS can be selected automatically as well
• >IP-Address<:
Address in the local network
• >Subnet mask<:
Description of the local network
• >Gateway<:
Address of a router (if existing only)
• >DNS<:
Addresses of name servers for address resolution; divided into primary and
secondary; only primary if >DNS automatic< is activated
35.2 Web server
Adjust the required settings for the remote control of the NivuFlow transmitter here. The web
server provides all operation function via Internet as an alternative to operation on site.
Access data to the web server are specified. Operation is carried out remotely using a web
browser via HTTP or a data transfer software application directly via the FTP server.
HTTP:
• >HTTP Acitve<:
Enable unencrypted access via port 80
• >HTTPS Active<:
Enable encrypted access via port 443