
- Page 23
-
6. Installation of Equipment
6.1.
Installation of EchoSmart Sensor
The EchoSmart Sensor must be fully submerged in the supernatant process liquid
during operation. It is not capable of transmitting a signal through gas (air) or solid
materials.
Mount the sensor using a rigid pipe or conduit to minimize excessive side-to-side sway
or other avoidable movement. If a surface skimmer is present, install using a sensor
mounting fixture that rotates the sensor out of the path of the skimmer (EDI Transducer
Multi-flex Assembly, Part No. 9300-13-13).
Orient the sensor such that the path of the transmit pulse is at 90˚ with respect to the
surface of the sludge blanket or other material that is to be measured, as illustrated in
Figure 6.1 (Entech Design Drawing #ESS-210).