npk411en2006h
1/4
Thank you for choosing NIVELCO instruments.
We are convinced that you will be satisfied with our product.
1. APPLICATION
NIVOPRESS N
submersible hydrostatic level transmitters are applicable for the continuous level measurement of clean
liquids or liquids with slight chemical contamination in wells, open reservoirs or tanks. The NC is recommended for level
detection of contaminated water.
NIVOPRESS N
is easy to install in tanks and deep wells, and especially recommended
for controlling submersible pumps. The use of supplemental accessories is recommended. Using a sewage adapter direct
contact between the sewage and the diaphragm of the built-in pressure sensor can be avoided. 2-wire types are available
with built-in 4-wire Pt100 temperature sensor or separate 2-wire temperature transmitter. 2-wire types have HART
®
communication interface. The Ex-types are available for explosion hazardous environments.
2. TECHNICAL DATA
SUBMERSIBLE PROBE
2-wire
3-wire
TYPE
NP, NF, NZ, NR
NC, NT
NK, NN,
ND, NH
NB, NG
N
H
Measurement range
(1)
0…200 mH
2
O 0…20
mH
2
O 0…200
mH
2
O 0…200
mH
2
O
As per order code
Overload allowed
(as a function of range)
3x
20x (
≤
3 mH
2
O)
10x ( >3 mH
2
O)
3x (
≤
20 mH
2
O)
2x ( >20 mH
2
O)
3x
Output
4…20 mA + HART
®
4…20 mA
4…20 mA + HART
®
0...+10 V (0 V
≤
80 mV)
Power supply
12…30 V DC
18…30 V DC / 6 mA
Load
(U
t
= power supply.;
U
min
= min. power supply 12 V)
min
max
0,02
t
U
U
R
A
≥
5 k
Ω
Built-in temperature sensor
HART
®
secondary value,
accuracy: ±3°C (±5.4°F)
–
HART
®
secondary value, accuracy:
±3°C (±5.4°F)
–
Thermal compensation error
(2)
±0.2%
Not applicable
±0.2%
Not applicable
Linearity error (level transmitter)
±0.25%
±0.45% (
≤
20 m H
2
O)
±0.25% ( >20 m H
2
O)
±0.25%
Temperature error
≤
±0.1% / 10 K
≤
± 0.1% / 10 K
≤
±0.2% / 10 K
Operating temperature
(3)
−
30…+60 °C (–22…+140 °F)
Process connection
NAA-209 cable mounting wedge clamp, threaded types with ¾
″
BSP thread
Ingress protection
IP68
Electrical protection
Class III
Electrical connection
Shielded cable with breathing capillary Ø7 mm (Ø0.275 inch)
Wire cross section
0.34 mm
2
(AWG 22)
Cable length
0…300 m (0…985 ft) as per order code; (Ex ia IIC: max. 100 m [328 ft])
Dimensions
NP, NF:
Ø22x173 mm
(Ø0.87 x 6.8")
NZ, NR:
Ø38x174 mm
(Ø1.5 x 6.85")
Ø40x146 mm
(Ø1.55 x 5.75")
NK, NN:
Ø22x173 mm
(Ø0.87 x 6.8")
ND, NH:
Ø38x174 mm
(Ø1.5 x 6.85")
Ø24 x 212 mm
(Ø1 x 8.3")
NPH:
Ø22 x 173 mm
(NPH: Ø0.87 x 6.8")
NZH:
Ø38 x 174 mm
(NZH: Ø1.5 x 6.85")
Mass
NP, NF:
probe: 0.2 kg (0.44 lb)
NZ, NR:
probe: 0.3kg (0.66 lb)
Probe:
0.4 kg (0.88 lb)
Probe: 0.2 kg (0.44 lb)
Cable: PUR cable: 0.065 kg/m, FEP cable: 0.072 kg/m
Additional temperature transmitter
N
D
types
Output: 4…20 mA; Power supply: 14…30 V DC;
Temperature range: 0…+60 ºC (+32…+140 ºF);
Accuracy: ±3 °C (±5.4 °F)
-
Additional temperature transmitter
N
P
types
Pt100B sensor, 4-wires
-
Material of
wetted
parts
Sensor
1.4404 or
(1.4571 and 1.4435)
Al
2
O
3
ceramic
1.4404 or
(1.4571 and 1.4435)
Housing 1.4571
POM-C
1.4571
Cable coating
Polyurethane / FEP
Sealing Viton
®
(FKM)
Protecting cap
1.4571
– 1.4571
POM-C
1.4571
(1)
m H
2
O means: 1 metre of water column,1 mH
2
O ~ 0.1 bar
(2)
valid if temperature compensation is active, can be switched in parameter HART - P10b
(3)
special order max. +75 °C (+167 °F)
2.1
A
CCESSORIES
User’s Manual
Warranty Card
EU declaration of Conformity
A
DDITIONAL
D
ATA FOR
E
X
C
ERTIFIED
M
ODELS
–
ATEX
A
PPROVAL
N
O
.:
BKI16ATEX0009
Type
N
–5
–
Ex
Power supply
14…30 V DC
Ex marking
Up to 100 m (328 ft) cable length:
II 1G Ex ia IIC T6 Ga, between 100 m (328 ft) and 300 m (985 ft) cable length:
II 1G Ex ia IIB T6 Ga
Reference document
npk4110m0600h_04
Temperature range
−
30…+60 °C (
−
22…+140 °F)
Intrinsically safe data
U
i
= 30 V, I
i
= 100 mA, P
i
= 0.8 W
for IIC gas group
: C
i
≤
52 nF, L
i
≤
1.4 mH (calculated with
100 m
[328 ft] integrated cable),
for IIB gas group
: C
i
≤
132 nF, L
i
≤
1.6 mH
A
CCESSORIES
Cable terminal box
NAA–101
Dimensions
93 x 93 x 55 mm (3.66 x 3.66 x 2.16 inch)
Ingress protection
IP65
Operating temperature
−
40…+70 °C (
−
40…+158 °F)
Material Polystyrol
Cable gland
M20x1.5 (cable outer diameter
5…
10 mm
[
0.2…
0.4 inch])
Electrical connection
Terminal block for cable with max. cross section
of 2.5 mm
2
(AWG 13)
Cable terminal box with
overvoltage protection*
NAA–102
Data See:
NAA-101
Electrical data
See: OVP
Cable mounting wedge clamp
NAA–209
Max. mech. load
300 m (985 ft) cable
Operating temperature
−
20…+60 °C (
−
4…+140 °F)
Overvoltage protection
OVP–12/33*, OVP–22/33*
OVP–32/33*
Mounting
outdoor
EN 60715 - 35 mm (1
⅜
inch) rail
Dimensions
72 x 42 x 19 mm
(2.8 x 1.65 x 0.75 inch)
62 x 65 x 18 mm
(2.44 x 2.56 x 0.7 inch)
Ingress protection
IP54
IP20
Breakdown voltage
33 V
Absorbed energy
600 W / 1 ms
Internal resistance
13
Ω
Leakage current
10
A
*only for 2-wire 4…20 mA equipments!
Adapters
Threaded spacer
Material
NAZ-101-0 ¾"
BSP
– ½" BSP
KO35 (1.4571)
NAZ-102-0 ¾"
BSP
– M20x1.5
NAZ-105-0 ¾"
BSP
– 1" NPT
NAZ-106-0 ¾"
BSP
– 1" BSP