background image

 

 

 

 

 

 

 

Model: 

AM706D

 

 

 

 

 

 

 

       

Weather Station 

Operation Manual 

Document:   NLT-AM706D-SSEN   
Edition:       V140827

 

 

 

 

 

Summary of Contents for AM706D

Page 1: ...Model AM706D Weather Station Operation Manual Document NLT AM706D SSEN Edition V140827...

Page 2: ...ess any button to mute Selectable Relative True speed direction Selectable day and night modes Direction calibration After power on move wind vane toward the ship bow direction then press the reset bu...

Page 3: ...r or rain into unit Operation Warn Do not refit unit privately Installation Warn Do not operate with water Be sure the main unit location is IP23 If water leakage Power down immediately Be sure the wi...

Page 4: ...r NMEA0183 7 GPS data input RMC 7 GPS data input GGA data input 8 GPS data input VTG 8 Speedlog data input VBW 9 Gyro data input HDT 9 Main unit output MWV 9 Main unit output MDA 10 Main unit output M...

Page 5: ...Mounting 22 Power Adapter Installation 23 Installation of Wind sensor AM706S 24 Wind Vane and Wind Cup Installation 24 Integral Installation 25 Temperature and Humidity Sensor Installation 26 Tempera...

Page 6: ...larly print these parameters and time longitude and latitude ship speed and navigational signal It is important and necessary for observation and safe navigation AM706D is approved by China Classifica...

Page 7: ...S485 to main unit through junction box Barometric pressure signal is received from internal IC sensor of main unit Main unit uses these signals to calculate display and export True speed and direction...

Page 8: ...3 System Introduction General View...

Page 9: ...Constitution Wind direction and speed sensor holder and junction box Wind direction sensor Wind indicator with empennage and weight and absolute value angle sensor near axis Wind speed sensor Three wi...

Page 10: ...power input 2 channels Temperature humidity input 1 channel NMEA0183 input 3 channels NMEA0183output 2 channels Printer output 1 channel Sound light alarm output 1 channel Power supply DC24V 20 32V O...

Page 11: ...ccuracy 1 Wind speed range 1 2 25m s Wind speed accuracy 5 min 0 1m s Min start speed 1 2m s Temperature range 20 80 C Temperature accuracy 0 5 C Humidity range 0 100 RH Humidity accuracy 4 5 RH Barom...

Page 12: ...l ll a yyyyy yy a x x x x xxxxxx x x a h h CR LF 1 UTC of position fix 2 Status A data valid V navigation receiver warning 3 Latitude 4 Latitude N S 5 Longitude 6 Longitude E W 7 Speed over ground kno...

Page 13: ...f precision 9 Antenna altitude above below mean sea level geoid 10 Units of antenna altitude m 11 Geoidal separation 12 Units of geoidal separation m 13 Age of differential GPS data 14 Differential re...

Page 14: ...alid 7 Stern transverse water speed Knots 8 Status stern water speed A data valid V data invalid 9 Stern transverse ground speed Knots 10 Status stern ground speed A data valid V data invalid 11 Check...

Page 15: ...ction 14 Wind direction unit degree T true 15 Relative direction 16 Relative direction degree M Relative 17 Wind speed 18 Wind speed unit N knots 19 Wind speed 20 Wind speed unit M m s 21 Checksum val...

Page 16: ...and ship bow 7 H HUM alarm Set Value Press H HUM to set alarm value or turn off 8 Current relative HUM Display current relative humidity No Display Explanation 1 Current relative tr ue wind speed Pres...

Page 17: ...dow and observe input signal Key Introduction Switch on off 0 OFF 1 ON Gust Alarm OFF 1 25m s High Temperature Alarm 20 80 OFF Low Temperature Alarm OFF 20 80 High Humidity Alarm OFF 1 99 RH Print Set...

Page 18: ...m When power failure alarm is triggered the main unit buzzer provides long tone alarm external alarm will not be on when power failure and red words Power Failure are flashing Alarm Mute When alarm is...

Page 19: ...ned on wind value color turns yellow to red and continuously flashing H TMP High Temperature Alarm Press left right arrows of H TMP to set the high temperature alarm and factory setting is OFF Set Val...

Page 20: ...continuously flashing H HUM High Humidity Alarm Press left right arrows of H HUM to set the high humidity alarm and factory setting is OFF Settings OFF 1 99 RH When current relative humidity is less...

Page 21: ...0 seconds DPU 414 Printer Setup Dip SW 1 1 OFF Input Serial 2 ON Printing Speed High 3 ON Auto Loading ON 4 OFF Auto LF OFF 5 ON Setting Command Enable 6 OFF Printing 7 ON Density 8 ON 100 Dip SW 2 1...

Page 22: ...nd 321 3 2m s 2 Temperature 16 2 Humidity 64 0 RH Barometer 1008hPa 3 03 08 32 01 2524N 118 42 0208E Heading 190 4 Speed 0 0Knots Note Do not print the messages on the third line when no GPS or course...

Page 23: ...nal window observe gyro speedlog GPS signal input situation Speed Unit m s km h kn Gust alarm and current measured values automatically convert with speed unit conversion Temperature Unit C F H L TEMP...

Page 24: ...Sensor Part When there is ice or dirt on sensor to disturb the normal work please clear in time Regularly check external mounting bolts to avoid looseness and the abrasion and ageing of cables When t...

Page 25: ...de Then open the junction box Press the calibration button in the waterproof junction box and display relative wind direction zero on main unit Close the waterproof junction box The groove on box body...

Page 26: ...n unit Installation AM706D The Main unit has three mounting methods table hanging and flush mounting Table and Hanging Mounting The holder supplied by original factory setting is used in table and hun...

Page 27: ...The holder supplied by original factory setting should be used in flushing mounting Embed the main unit into the bridge control panel the dimension is shown below and tighten the rotary knob to fix t...

Page 28: ...23 Power Adapter Installation Power adapter GA 240150 AC220 110V to DC24V adapter holder and screws Unit mm...

Page 29: ...o black seal ring plane washer spring washer and 2 screw nuts The two screw nuts should be tightened and then insert the cotter Wind Cup Wind cup is installed on the bottom of sensor holder successive...

Page 30: ...n Use U bolt in the accessory to fix wind sensor and the best option of supporting tube diameter is 60mm Wiring 4 core screened cable with external diameter 4mm 6mm is connected with 4 terminals B A t...

Page 31: ...rature and Humidity Sensor AM706TH Temperature and humidity sensor AM706THcan be installed in hung and fixed link mounting methods AM706TH with M10 bolt is installed on the vertical wall or with U blo...

Page 32: ...27 Wiring explanation Wiring diagram of AM706D back cover...

Page 33: ...28 System internal connection System internal wiring diagram...

Page 34: ...t AM706D 4 core screened cable with external diameter 3mm 6mm is connected with 4 terminals B A through glands of junction box Please pay attention to wire colors and sequence in order to correctly co...

Page 35: ...30 Main unit AM706D Power in Connect DC cable and ac power adapter GA 240150 with ship power...

Page 36: ...31 System external connection System external wiring diagram...