High-frequency Microwave Sensor
PD-V19 instruction
www.pdlux.com
Tel: 86-574-83008608
Add: 17F,Commerce Building of NingBo,
No 588, South Tiantong Rode,Yinzhou District,Ningbo
,
China
Application
Feature and advantage
Intelligent switch
Intruder detect
Low wireless power output
Low power consumption
Non-contact detection
Easy to connect with the controller
Wall-hung switch
Low noise output
Antenna Beam Pattern
This module is ideally suiable for occupancy sensor in automatic lighting
switches.It can also be used for ceiling mount intruder detectors.
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
150°
160°
170°
180°
190°
200°
210°
220°
230°
240°
250°
260°
270°
280°
290°
300°
310°
320°
330°
340°
350°
-70
-60
-50
-40
-30
-20
-10
0
Horizontal
Vertical
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
150°
160°
170°
180°
190°
200°
210°
220°
230°
240°
250°
260°
270°
280°
290°
300°
310°
320°
330°
340°
350°
-56
-48
-40
-32
-24
-16
-8
0
360°
180°
Products size
Block diagram
and connection
+5V
IF
Tx/Rx Antenna
GND
Mixer
Oscillator
PD-V19 5.8GHz 360º/180ºMicrowave Motion Sensor is a C-Band Bi-Static
Doppler transceiver modlue .It’s built-in Resonator Oscillator (CRO).This
module
,
V8 adopts flat Plane Antenna, suitable for wall mounting. It can
improve its front signal receiving ability and reduce its flank blind area. Its
performance is better than the sensors in the market.
PD-V19 5.8GHz 360º/180º Microwave Motion Sensor
5.4mm
XXmm
20.5mm
26.0mm
+5V
Signal output
Pre-amp
According with FCC Part 15.249
According with EN 62321,ROHS directive-2011/65/eu
According with REACH directive-1907/2006/ec
According with EN 300440-V2.1.1
、
EN 62479
:
2010,RED
directive-2014/53/eu
Products size
Radiated Power (EIRP)
Supply Voltage
Current Consumption
Current Consumption
Operating Temperature
Weight
Parameter
Frequency Setting
Storage environment
Symbol
Fstandard
Pout
VCC
ICC
ICC
TOP
TSTG
Weight
Min
4.75
10
13
-10
3.3
Typ
5.80567
3.54
5.0
12
15
25
3.8
Max
5.25
14
17
90
4.3
Units
GHz
dBm
V
mA
mA
℃
℃
mm
g
Notes
FCC
CE
20-70% RH humidity
0-40
26.0x20.5x5.4
Note: X height can be customized according to customer requirements.
Tel: 86-574-
65325018
Fax: 86-574-
65325000
Email: [email protected] Web: www.pdlux.com