4.3 Apply Power
Insert the included 5V power adapter into the NL-M1DK:
Plug the power supply into a power outlet.
4.4 Verify COM Port Enumeration
Open Windows Device Manager, and verify that the FTDI drivers installed properly.
There will be two new COM ports on your PC. You will use the first COM port for AT
commands. The second COM port is a debug port, and not usable by the end-customer.
Note the first COM port number. For this guide, the ports enumerate as COM44 and
COM45:
If your devices do not install, you may need to download drivers from FTDI. Please find
them here:
http://www.ftdichip.com/Drivers/VCP.htm
4.5 Connect to the Skywire
Open TeraTerm, and close the initial connection window that appears: this window
doesn't allow us to change the baud rate. Go to:
Setup > Serial Port
PN 30192 rev 10
© NimbeLink Corp. 2018. All rights reserved.
14