Electrical System
63
Service Manual – Floortec R 870
Fuses
All circuits and components are protected by fuses, located inside or outside the electrical component box. To
protect motors from overloads when using the machine, there are manually resettable fuses (side brooms) or
fuses interlocked to electronic protection systems (main broom, see Main Broom Motor Protection in Dash
-
board Electronic Board Specifications chapter).
All the circuits are protected by non-resettable fuses
Pos.
Type
Battery Versions
Petrol and LPG Versions
Nominal
Size
Protected Function
Nominal
Size
Protected Function
F0
Not resettable
150
GENERAL
150
GENERAL
FA
Not resettable
50
MAIN BROOM
50
MAIN BROOM
FC
Not resettable
-
-
80
BATTERY/DYNAMOTOR RECHARGE
FR1
Resettable
15
RIGHT SIDE BROOM
15
RIGHT SIDE BROOM
FR2
Resettable
15
LEFT SIDE BROOM
15
LEFT SIDE BROOM
F1
Not resettable
25
VACUUM SYSTEM
30
VACUUM SYSTEM
F2
Not resettable
25
FILTER SHAKER
30
FILTER SHAKER
F3
Not resettable
3
KEY CIRCUIT
3
KEY CIRCUIT - EV LPG
F4
Not resettable
10
HORN - PIVOTING LIGHT - HEADLIGHT
10
HORN - PIVOTING LIGHT - HEADLIGHT
F5
Not resettable
5
WATER PUMP
5
WATER PUMP
F6
Not resettable
25
HOPPER PUMP
30
HOPPER PUMP
F7
Not resettable
25
SPARE
30
SPARE
F8
Not resettable
10
SPARE
10
SPARE