Dust Guard System
57
Service Manual – Floortec R 870
Nozzle and Filter Cleaning
1
Drive the machine on a level floor.
2 Turn the ignition key to “0” and engage the parking brake
3
On the front side of the side brooms, remove the ring nuts (A) (bayonet joint).
4
Remove and clean the nozzles (B), the gaskets (D) and the filters (C) with compressed air. Remove any
calcium deposit. If necessary, replace the filters (C).
5
Reinstall the filters, gaskets and the nozzles, then fasten them with the ring nuts.
B
D
C
A
A
P200113