Dust Control System
30
Service Manual – Floortec 760
Maintenance and Adjustments
Panel dust filter, cleaning and integrity check/replacement
Caution! The dust filter must be
regularly cleaned to
maintain the efficiency of the
vacuum system. Follow the
recommended filter service
intervals for the longest filter
life.
Warning! To clean the filter, always wear
safety guards (such as safety
glasses, dust mask, gloves,
etc.) and clean the filter in a
well-ventilated area. Take care
not to pierce the filter.
Note:
Besides the standard polyester
filter, paper filters are also
available.
1 Drive the machine on a level floor and ensure
that it cannot move
2 Turn the ignition key to “0”
3 Remove the hopper by using its transport handle
and wheels
4 If equipped, remove the pre-filter (A) after
releasing the upper fasteners (B) and then the
lower fasteners (C)
5 Disengage the lever fasteners (D) and turn down
the filter holder assembly (E) to the end-of-
stroke (F)
P200265