110
Service Manual – SC401, SCRUBTEC 344
24 - Electrical System (Battery)
Maintenance and Adjustments
Setting the Installed Battery Type
Set the electronic board of the machine according to the type of batteries installed (WET or GEL) as shown
below:
1 (If equipped) Turn the ignition key to “I”
Press the main push-button
to turn on the machine, then detect the current setting by checking
in the very first seconds the battery symbol LED flashing.
Figure 4:
GEL / AGM
WET
2 If the setting is to be changed, press the vacuum button
for 3 seconds
3 Within 3 seconds, shortly press the vacuum button
to select a new setting
4 Wait 3 seconds for the battery symbol to display the battery charge status
Note:
This procedure sets only the low voltage cut out threshold values and not the charging
profiles. In order to set the charger see the next procedure.
WARNING: In the machines equipped with on-board battery charger, the installed batteries (WET
or GEL/AGM) may require a specific charging algorithm. See the next procedure.