ENGLISH
INSTRUCTIONS FOR USE
22
SC401 - 9100002290
09/2017
SOLUTION FILTER CLEANING
1.
Drive the machine on a level floor.
2.
Ensure that the machine is off and the ignition key (41) has
been removed (if equipped).
3. Close the detergent solution tank valve (A, Fig. 9). The
valve is closed when it is in position (B) and it is open when
it is in position (C).
4. Remove the transparent cover (D) and the gasket (E), then
remove the filter strainer (F). Wash and rinse them, then
refit them carefully onto the filter support (G).
5. Open the valve (A).
DETERGENT TANK AND DETERGENT SYSTEM
CLEANING
(For machines with Detergent System)
Clean the detergent tank (17) as follows.
1. Drive the machine to the appointed disposal area.
2.
Ensure that the machine is off and the ignition key (41) has
been removed (if equipped).
3. Lift the cover (34) and check that the recovery tank (33) is
empty; if not, empty it using the drain hose (12).
4. Close the cover (34).
5. Grasp the handle (16) and carefully lift the tank (33).
6. Unscrew the cap (A, Fig. 10) from the detergent tank (B).
7. Remove the tank.
8. Rinse and wash out the tank with clean water in the
appointed disposal area.
NOTE
For a thorough washing of the Detergent System, the
cleaning procedure can also be performed with the
detergent tank (17) full of water.
Turn on the system with the flow set to the maximum
(see the procedure in Use/Operation chapter).
It is advisable to perform this type of cleaning when
the Detergent System is dirt/furred up, because the
machine has not been used/cleaned for a long time.
9.
Replace the detergent tank (B) as shown in the figure, then
refit the plug (A).
D
F
E
G
A
C
B
Figure 9
P100957
B
A
Figure 10
P100958
9100002290(A)09-2017.indb 22
24/10/2017 14:24:07