24 - Electrical System
Battery Charge State Display
Low voltage cut out
The Main machine controller (EB1) shuts off electrical loads to protect the batteries from damage caused by
over discharging
The voltage threshold where loads are turned off depends on the battery type See table below
Significant levels for machine operation
INDICATION
TRANSITION THRESHOLD
(VOLT)
CONSEQUENCE
WET
GEL
1
22V
22.2V
Little remaining run time, no block.
2
20.4V
21.6V
Brush OFF
3
19.4V
20.6V
Vacuum system OFF
4
18.4V
19.6V
Drive system OFF