Service Manual-
AS1050R
40 Recovery System 106
Troubleshooting
Trouble
Possible causes
Remedy
The vacuum motor
can
’t be turned on
Wiring damaged
Repair/replace
Main Controller (EB2) fault
Replace
Vacuum motor damaged
Check the amperage/replace
Recovery sensor (SW5) is activated
Drain the recovery tank
Circuit breaker (F5 or F6) is opened
Reset the circuit breaker
Vacuum Motor Current Draw Test
Warning! This procedure must be performed by qualified personnel only.
1. Apply amp clamp (A, Figure 10) to one of the vacuum motor cables (B, Figure 10).
2. Insert ignition key to switch on machine.
3. Start vacuum motor by pressing vacuum button.
4. Check if current draw of motor is between 16A and 20A at 36V for one vacuum motor system.
5. If amperage is higher than 20A, perform following procedures to determine cause and correct abnormal
amperage:
•
Check and replace vacuum motor carbon brushes if necessary.
•
Remove vacuum motor and check condition of all components, repair or replace them if necessary.
If above-mentioned procedures
can’t get amperage correct, it is necessary to replace vacuum motor.