background image

Optos Arm Rest 

Installation and User Guide 

G112883-006-ENG 

 

 

 

Technical specifications 

 
 
 

 
Note

: The arm rest height does not include the height from the floor to the table 

base where the arm rest connects. 

 
 
 
 
 
 
 
 
 

 

Warnings and cautions

 

The Optos arm rest MUST be operated within the safety parameters and instructions defined in the 

Optos Table User Guide.

 

If you have any questions regarding the correct use of the Optos arm rest, please contact your Optos representative before 

attempting to operate the Optos arm rest. 
 

 

WARNING 

Do NOT lean on the arm rest. 
Ensure the patient or operator’s arm is NOT trapped or impacted when the arm 

rest position is adjusted or when Optos table height is adjusted. 
Incorrect positioning of the arm rest MAY result in patient harm. 

 

 

CAUTION 

 
The Optos Table legs and arm rest fixing points protrude. The patient and 

operator must take care when moving around the table. 
If you suspect the arm rest is faulty, or if the pad becomes worn or damaged, 

please contact your Optos representative. 
In order to prevent any contamination always clean and disinfect parts of the 

equipment which will be in contact with the patient. 
Avoid contact with injured skin or mucous membranes. 
Be careful NOT to damage the arm rest when cleaning. 
You should be aware of your contractual obligations before disposing of any 

equipment. 

 

 

Dimensions 

Details 

Width 

12 cm (5 inches) 

Depth 

35 cm (14 inches) 

Arm rest height

 

55 cm to 75 cm (22 inches to 30 inches) 

Arm rest weight 

1.7 kg (3.8 lbs) 

Maximum load on Arm rest 

15 kg (33 lbs) 

Summary of Contents for Optos G112883-006

Page 1: ...Optos table height is adjusted Incorrect positioning of the arm rest MAY result in patient harm CAUTION The Optos Table legs and arm rest fixing points protrude The patient and operator must take care when moving around the table If you suspect the arm rest is faulty or if the pad becomes worn or damaged please contact your Optos representative In order to prevent any contamination always clean an...

Page 2: ...nts loosening 5 Nut Prevents loosening 6 Rubber cap Covers the unused adapter 1 Insert the screw 2 through the adapter 3 and nord lock washer 2 Insert the nut 5 with the nord lock washer 4 to the bottom of the base Hand tighten the nut 5 on to the screw 2 3 Tighten the connection using a hex key and a wrench 4 Attach the second adapter to the table s other leg 5 Cover the adapter with a rubber cup...

Page 3: ...er cup 2 Pull the arm rest up and twist it to remove it from the table leg 3 Insert the arm rest into the adapter twisting it counter clockwise to follow the pattern cut out You should feel resistance when it s in the right place then push it into the adapter onto the other table leg 4 Fit the retained rubber cup to the adapter on the unused table leg Adjusting the height 1 Loosen the height adjus...

Page 4: ...sition the arm rest so the pad 1 is parallel with the edge of the table 2 and does not create a clash hazard 2 Position the patient s arm so that it lies along the length of the arm rest pad Contact us Visit optos com to find your local contact details Copyright 2019 2021 Optos plc All rights reserved Optos plc products are protected by patents and patent applications listed at optos com patents T...