5
Menu Key
106
Total Station NPL-322 Instruction Manual
To store the point as an MP record and return to the
point input screen, press
[ENT]
in the Z field. The default
PT is incremented to the next value.
Calculating area and perimeter
To calculate an area or perimeter, press
[3]
or select
Area & Perim
in the Cogo menu.
To take a measurement, enter the first point and press
[ENT]
, or press the
MSR
softkey.
In the upper right corner of the screen, a counter
indicates how many points you have entered.
To input point numbers consecutively, use the
Fr/To
softkey. For more information, see
Entering a range of points, page 107
If you enter a new point name, you can enter new
coordinates and record the point. If you do not want to
record the point, press
[ENT]
without entering a value in
the PT field. An XY coordinate input screen appears.
Continue to enter points until you have defined all the
points in the lot. Then, press
[v]
to calculate the area and
perimeter.
Press
[ENT]
to store the calculated values as a a comment
record, or press
[ESC]
to return to the Cogo menu.
You can record NE, NEZ, or Z-only data to the database.
The first and last points that you enter are joined to close the area.
You must enter the points in the order in which they define the lot.
You can enter up to 99 points.
Summary of Contents for NPL-322
Page 14: ...Contents xiv Total Station NPL 322 Instruction Manual ...
Page 38: ...2 Preparation 24 Total Station NPL 322 Instruction Manual ...
Page 68: ...3 Getting Started 54 Total Station NPL 322 Instruction Manual ...
Page 110: ...4 Applications 96 Total Station NPL 322 Instruction Manual ...
Page 154: ...5 Menu Key 140 Total Station NPL 322 Instruction Manual ...
Page 161: ...Total Station NPL 322 Instruction Manual 147 Checking and Adjustment 6 ...
Page 162: ...6 Checking and Adjustment 148 Total Station NPL 322 Instruction Manual ...
Page 172: ...8 System Diagrams 158 Total Station NPL 322 Instruction Manual ...
Page 188: ...9 Communications 174 Total Station NPL 322 Instruction Manual ...