Applications
4
Pulse Laser Station NPL-302 Series Instruction Manual
99
Measuring distance and offset values on the vertical plane
40.1
1.
To enter the 2-Pt Reference Plane function,
press
[6]
or select
V-Plane
in the Programs menu.
2.
Enter two points to define the plane.
–
To enter the point by direct measurement,
press the
MSR
softkey.
When you press the
MSR
softkey, a temporary
observation screen appears.
3.
Press
[MSR1]
or
[MSR2]
. The Record PT screen
appears.
You can use an REM measurement to update the height of target. Take a
measurement to the prism, sight the bottom of the prism pole, and press
[ENT]
.
Baseline