Nikon Digital Camera System Brochure Download Page 4

PC based camera control unit

Imaging Software

This compact control unit can be connected quickly to a Windows® based PC
via its USB2.0 interface, without the need for a separate PCI board.

By controlling the camera with a PC, the user can expand their system, not only
to facilitate image capture but also results analysis, and image processing with
Nikon's ACT-2U Multi-functional imaging software. 

Two USB ports are provided.
Connects to a PC via USB2.0 interface (USB2.0 offers both wide compatibility and high
data transfer speeds), which enables camera control and live image display at high
speed on a monitor.

A variety of screen layouts

Standard Layout, 
for straightforward operations

1

2

3

4

5

Tool bar

Frequently used menu items are displayed as
buttons

Captured image screen

Display of the captured image

Live image screen

Properties dialog box

For display/alteration of the camera’s current
settings

Image thumbnails

Advanced Layout, 
adding useful functions

7

8

Toolbox

Tool buttons for processing and analysis of
images

Process view window

Analysis of focus, profile and histogram
Displays analytical settings for control and
focus

7

8

4

6

5

2

1

Settings box, which allows detailed
customizing of the screen layout, in
addition to the standard and advanced
layout.

Scene mode for one-click optimal photography

A variety of measurement tools

Key functions

Area

The area inside an enclosure, outlined by
the mouse, is automatically calculated

Screen patterns

Grid or concentric circle patterns can be
displayed.

Superimposition using the Merge function

It is easy to produce merged images of multistained fluorescence sam-
ples using monochrome photography. When you acquire images after
initially setting the number of layers and display colors for each
reagent, colored images will be automatically displayed. By changing
the wavelength for each acquisition, this function easily allows a super-
imposed image to be produced.

Interactive control of the microscope and camera

In combination with the ECLIPSE 90i motorized microscope, it is possible to
control the 90i from the ACT-2U menu and to automatically detect and record
the microscope status data with the image, including the objective magnifica-
tion and fluorescence filter in use. Automatic detection of status is also possi-
ble when combined with the ECLIPSE 80i microscope configured with a digi-
tal imaging head.

The control software of the 90i and digital imaging head can be easily
accessed from ACT-2U.

Tool Bar:

1. Main Tool Bar
2. Tool Box
3. Annotation Tool Box
4. Graphic Annotation Setup

Recording Mode:

1. Average Recording
2. Time Lapse Recording
3. Variable Time Lapse Recording
4. Z Stack Recording

Image Processing:

1. Direction/Resize Control
2. Crop Control
3. Duplicate Control
4. Kirsch Filter
5. Sobel Filter
6. Laplace Filter
7. Low Pass Filter
8. Median Filter

Process View
Thumbnail Window
Experimental Information
Window

Printing:

1. Print Main Menu
2. Print Preview Mode
3. Layout Edit Mode

File Operation

Camera Control:

1. Hardware Connection Dialog Box
2. Control Window
3. Property Window

Microscope Control:

1. Hardware Connection Dialog Box
2. Microscope Control
3. Pixel Divide Function Setup
4. Fixed Scale Bar Setup

Image Display:

1. 2D Image View
2. 2D Quadrant View
3. 3D Orthogonal View
4. 3D Tiling View

Image Analysis:

1. Focus Analysis
2. Profile Analysis
3. Histogram Analysis
4. Area ROI Analysis
5. Line ROI Analysis

The configuration offers a standard screen layout and advanced layouts with a high
degree of image analysis functionality. Each layout can be customized according to need. 

7

6

Layout customizing window

6

Capture window

Basic image capture control window 
Scene function for one-click optimal photog-
raphy

Single cable connection to a PC via USB2.0 interface.
Extremely versatile imaging software that is easy to operate,
and has a wealth of functions to suit almost any needs.

Scale display

XY scale display

point to line
distance

Circular measurement

(displays diameter, circum-

ference, center of gravity)

Angle

(intersection)

Distance
measurement

For 

fluorescence 

/

darkfield

observations

For 

brightfield 

observations

For

DIC 

/

phase contrast

observations

For 

wafer 

IC chip 

images

For 

metal 

ceramic

material images

For 

printed circuit board

images

3

Summary of Contents for Digital Camera System

Page 1: ...Digital Camera Digital Sight Series Digital Camera System for Microscopy ...

Page 2: ... For extremely clear color fluorescence images With its built in Peltier cooling mechanism the tem peratureof the 5 0 megapixel color CCD can be main tained at 20 C below room temperature Thermal noise is thus greatly reduced during long time expo sure DS 2MBWc DS 2MBW The 2MBWc incorporates a Peltier cooling mechanism that minimizes thermal noise Its 2 megapizel mono chrome CCD boasts a sensitivi...

Page 3: ...work or remotely control the camera from a network In combination with the ECLIPSE 90i motorized microscope it is possible to control the 90i from the DS L1 menu and to automatically detect and record the microscope status data with the image including the objective magnification and fluorescence filter in use Automatic detection of status is also possible when combined with the ECLIPSE 80i micros...

Page 4: ...motorized microscope it is possible to control the 90i from the ACT 2U menu and to automatically detect and record the microscope status data with the image including the objective magnifica tion and fluorescence filter in use Automatic detection of status is also possi ble when combined with the ECLIPSE 80i microscope configured with a digi tal imaging head The control software of the 90i and dig...

Page 5: ...nd alone control unit which does not require connection to a PC is a real space saver Camera conditions most appropriate to the illumina tion techniques used can be chosen from a menu allowing anybody to easily capture beautiful images A reasonably priced monochrome configuration Easily takes high contrast monochrome images in observations such as phase contrast and DIC Using a high frame rate cam...

Page 6: ...ing Ethernet 10 100Base TX DHCP compatible HTTP TELNET or FTP server FTP client LCD monitor 6 3 in TFT color LCD XGA 1024 x 768 60Hz External monitor output Analog RGB SXGA 1280x1024 60Hz XGA 1024x768 60Hz Storage media CompactFlashTM card Type 1 Type II Direct printing Optional accessories ACT 2U Imaging Software System Requirements Computer type MS DOS PC supporting USB2 0 CPU Pentium 4 1 7GHz o...

Page 7: ...1 9414 0 fax 49 211 9414 322 NIKON INSTRUMENTS S p A ITALY phone 39 55 3009601 fax 39 55 300993 NIKON AG SWITZERLAND phone 41 43 277 2860 fax 41 43 277 2861 NIKON UK LTD UNITED KINGDOM phone 44 20 8541 4440 fax 44 20 8541 4584 NIKON INSTRUMENTS INC 1300 Walt Whitman Road Melville N Y 11747 3064 U S A Phone 1 631 547 8500 1 800 52 NIKON within the U S A only fax 1 631 547 0306 www nikonusa com NIKO...

Reviews: