62
Reference: The Tool Chest
Slide Feeder Scan (4000 ED/LS-2000 only)
This option is available when the SF-200 (S) slide feeder (sold
separately) is inserted in the 4000 ED or LS-2000. To specify
the number of slides scanned when the Scan button is clicked,
enter the desired number in the Feed Images text box. To
scan all slides in the feeder, enter a large value, for example
“999.”
Method
Description
Panorama
The initial crop is adjusted to suit the “pan-
orama” setting for APS (IX240) cameras.
Classic
The initial crop is adjusted to suit the “clas-
sic” setting for APS (IX240) cameras.
Wide
The initial crop is adjusted to suit the “wide”
setting for APS (IX240) cameras.
IX240 Crop Choices
IX240 crop choices for APS (IX240) film are available when the
IA-20 (S) adapter (sold separately) is inserted in the 4000 ED,
COOLSCAN IV ED, LS-2000, or COOLSCAN III.
The following crop choices are available: