HD-610P
HIGH FREQUENCY SENSOR MODULE
1
INTRODUCTION
1.1 Characters of high frequency sensor module
1.1.1 High frequency signal is able to penetrate non-metallic materials such as
the wood board, brick wall, glass, etc., but it can not penetrate the water
and metal. It is possible to change the signal direction by using a metallic
shield to adjust sensor’s detection coverage.
1.1.2 High frequency sensor module has high reliability and its detection range is
less affected by temperature (0°C to +70°C), airflow, wind, etc..
1.1.3 Mainly for indoor application and it is possible to be installed under large
eaves, higher sensitivity in a smaller inner space.
1.1.4 The product can be installed in a closed non-metallic lamp housing.
1.1.5 The humidity, vibration as well as measurement of moving object can
weaken the performance of high frequency sensor.
1.1.6 The sensor is more sensitive for moving in different speeds which lead to
larger detection range and it is less sensitive for moving in same speed,
therefore, the detection range could be reduced.
1.1.7 Although the high frequency sensor can be activated by the snow & rain, it
is good for safety because the ambient light will turn to be darker while
snowing & raining.
1.2 It is easy to be false triggered because of its strong penetrability of
non-metallic materials and high sensitivity. The location of the
sensor module is very important.
2
HELPFUL TIPS FOR INSTALLATION
2.1 DO NOT install the sensor module in a closed space made of metal.
2.2 Avoid mounting the lighting fixture with sensor module at the place where is
easily vibratile.
2.3 Avoid installing the sensor module in lamp housing of the thickness over
5mm, otherwise, the detection range will be shortened for nearly 20%.
2.4 Be aware of the temperature inside lamp housing should be lower than
+70°C.
2.5 It is recommended to mount the sensor module on the material of plastic,
wood or PVC instead of metal if the lamp is made of different materials.
2.6 Ensure the sensor module is installed at least 60mm away from ballast, lamp
holder, or bulb with filament (See FIG.1).
A circuit breaker (250VAC, 6A) type C according to EN60898-1 of load
Ⅰ
shall be installed in the fixed wiring for protection.
Do not mount on conductive surface.
Do not open the enclosure frequently.
Turn off power when change the light sources.
High in-rush current would be caused when bulbs of certain brands burned
which might damage the unit permanently.
CAUTION!
Only for your sample installation & testing reference purpose.
This instruction manual will not be attached with product for
regular order.
Load (L ) For Lighting:
Frequency
5.8GHz
For ceiling mount: 360
o
, about
Φ
10m at the height
of 2.5m
Operating Temperature
Environmental Protection IP20, Class
Ⅱ
Rated voltage
3
TECHNICAL SPECIFICATIONS
Incandescent Lamp
: Max. 1000W
AC Halogen Lamp
: Max. 500W
LV Halogen Lamp
: Max. 200W
Fluorescent Lamp
: Max. 200W (electronic)
2 x (1 x 58W); 4 x (1 x 36W);
8 x (1 x 18W); 1 x (2 x 58W);
2 x (2 x 36W); 4 x (2 x 18W)
Max. 160W / 20
µ
F
(compensated)
LED Lamp
: Max. 200W
Energy Saving Lamp: Max. 150W (include CFL
and PL lamp)
0
o
C to +70
o
C
Detection Range
Adjustable from approx. 5sec to 30min & Test
Auto Off Time
Adjustment
Meter Adjustment
Adjustable from approx. 5Lux to (∞)
Adjustable from “-” (approx.
Φ
2m) to “+”
( approx.
Φ
10m)
Lux Adjustment
FIG.1
ballast
>60mm
Sensor module
Lamp holder
>60mm
>60mm
Sensor module
>60mm
ballast
>60mm
5
DETECTION PATTERN
5.1 The detection pattern shown below means the sensor module is not installed
in lamp housing since that will reduce the detection area according to
different materials of lamp housing.
FIG.3
R 5m
R 1.5m
Major motion
Minor motion
2.5m
3m
10m
5.2 Usage of metal shield (optional purchase)
5.2.1 Fixing metal shield: insert the metal shield into the groove of housing
(See FIG.4).
FIG.4
Groove
Groove
230V~±10% 50 / 60Hz
Load
Dimension:
90 x 31.5 x 51mm (See FIG.2)
4
DIMENSION
FIG.2
51
84
90
31.5
For
Φ
3mm
screw
Photo sensor
(DO NOT cover it)
LED