background image

HD-610P

HIGH FREQUENCY SENSOR MODULE

1

 INTRODUCTION

1.1 Characters of high frequency sensor module

1.1.1 High frequency signal is able to penetrate non-metallic materials such as 
         the wood board, brick wall, glass, etc., but it can not penetrate the water 
         and metal. It is possible to change the signal direction by using a metallic 
         shield to adjust sensor’s detection coverage. 
1.1.2 High frequency sensor module has high reliability and its detection range is
         less affected by temperature (0°C to +70°C), airflow, wind, etc..
1.1.3 Mainly for indoor application and it is possible to be installed under large 
         eaves, higher sensitivity in a smaller inner space.
1.1.4 The product can be installed in a closed non-metallic lamp housing.
1.1.5 The humidity, vibration as well as measurement of moving object can 
         weaken the performance of high frequency sensor.
1.1.6 The sensor is more sensitive for moving in different speeds which lead to 
         larger detection range and it is less sensitive for moving in same speed, 
         therefore, the detection range could be reduced.
1.1.7 Although the high frequency sensor can be activated by the snow & rain, it
         is good for safety because the ambient light will turn to be darker while 
         snowing & raining.

1.2 It is easy to be false triggered because of its strong penetrability of
      non-metallic materials and high sensitivity. The location of the 
      sensor module is very important.

2

 HELPFUL TIPS FOR INSTALLATION 

2.1 DO NOT install the sensor module in a closed space made of metal.
2.2 Avoid mounting the lighting fixture with sensor module at the place where is 
      easily vibratile.
2.3 Avoid installing the sensor module in lamp housing of the thickness over 
      5mm, otherwise, the detection range will be shortened for nearly 20%.
2.4 Be aware of the temperature inside lamp housing should be lower than 
      +70°C.
2.5 It is recommended to mount the sensor module on the material of plastic, 
      wood or PVC instead of metal if the lamp is made of different materials.
2.6 Ensure the sensor module is installed at least 60mm away from ballast, lamp
      holder, or bulb with filament (See FIG.1).

A circuit breaker (250VAC, 6A) type C according to EN60898-1 of load

shall be installed in the fixed wiring for protection.
Do not mount on conductive surface. 
Do not open the enclosure frequently.

Turn off power when change the light sources.

High in-rush current would be caused when bulbs of certain brands burned 
which might damage the unit permanently.  

CAUTION!

Only for your sample installation & testing reference purpose. 
This instruction manual will not be attached with product for 
regular order.

Load (L  ) For Lighting:  

Frequency

5.8GHz
For ceiling mount: 360

o

, about 

Φ

10m at the height

of 2.5m

Operating Temperature

Environmental Protection IP20, Class 

Rated voltage 

3

 TECHNICAL SPECIFICATIONS

Incandescent Lamp

  

: Max. 1000W

AC Halogen Lamp

  

 

: Max. 500W

LV Halogen Lamp 

  

 : Max. 200W

Fluorescent Lamp 

 

  : Max. 200W (electronic)

                               2 x (1 x 58W); 4 x (1 x 36W);
                               8 x (1 x 18W); 1 x (2 x 58W);
                               2 x (2 x 36W); 4 x (2 x 18W)
                               Max. 160W / 20

µ

                               (compensated)
LED Lamp          

  

   : Max. 200W

Energy Saving Lamp: Max. 150W (include CFL 
                               and PL lamp)

0

o

C to +70

o

C

 

Detection Range

Adjustable from approx. 5sec to 30min & Test

Auto Off Time
Adjustment

Meter Adjustment

Adjustable from approx. 5Lux to     (∞)
Adjustable from “-” (approx. 

Φ

2m) to “+” 

( approx. 

Φ

10m) 

Lux Adjustment

FIG.1

ballast

>60mm

Sensor module

Lamp holder

>60mm

>60mm

Sensor module

>60mm

ballast

>60mm

5

 DETECTION PATTERN

5.1 The detection pattern shown below means the sensor module is not installed
      in lamp housing since that will reduce the detection area according to 
      different materials of lamp housing.

FIG.3

R 5m

R 1.5m

Major motion 

Minor motion

2.5m

3m

10m

5.2 Usage of metal shield (optional purchase)

5.2.1 Fixing metal shield: insert the metal shield into the groove of housing 
         (See FIG.4).   

FIG.4

Groove

Groove

230V~±10% 50 / 60Hz  

Load

Dimension: 

90 x 31.5 x 51mm (See FIG.2)

4

 DIMENSION

FIG.2

51

84

90

31.5

For 

Φ

3mm

screw

Photo sensor
(DO NOT cover it)

LED

Reviews: