HR15/17N HYBRID DC
2.4.5
Engine Coolant Specifications
Use permanent type (PT) for the Kubota D722 engine.
When anti-freeze is mixed with water, the ratio must be
less than 50%
, see table below.
2.4.6
Hydraulic Pressure Settings
Refer to hydraulic schematic as supplied with the machine noting the serial number of the Niftylift.
2.5
Tyre specifications
Standard tyre fitment:
Solideal Safety Master 33x12-20.
DO NOT REPLACE TYRES WITH ANYTHING OTHER THAN THE ABOVE
SPECIFICATION. CONSULT NIFTYLIFT PRIOR TO REPLACEMENT.
Volume % Anti-freeze
Freezing Point
Boiling Point
°C
°F
°C
°F
40
-24
-12
106
222
50
-37
-34
108
226