background image

 

 

 

 

 

List of light bulbs used in the signalling system 

 

license plate lamp 
front position lamp 

12V/5W fuse 

rear position lamp 

12V/5W bayonet 

direction indicator 
brake lights 
fog lamp 

12V/21W bayonet 

 

LED lights can be used optionally. 

 

6. BODYWORK 

 

 

KITCHEN SET 

 

COOLER 

 

Coolers used by NIEWIADÓW Sp. z o.o. have three power sources: 

- 230V 
- 12V 
- propane-butane gas. 

A detailed description of the operation, use and technical data of the 

cooler can be found in the supplementary manual (additional equipment). 

 

 

INTERIOR HEATING 

 

Caravans  may  be  fitted  with  interior  heating  units  powered  by  propane-

butane gas with a working pressure of 30mbar. 

To start the heater: 
 - connect the gas cylinder through a suitable reducer 

The kitchen set includes a gas stove and a sink. These items have dark glass 

lids. 
The stove is adapted for propane-butane gas combustion and can be connected 
to a gas cylinder only through a suitable pressure reducer (30mbar). 
When using a stove in the caravan, provide a continuous exchange of air to ensure 
that there is sufficient air for gas combustion and for fumes to escape (open vents 
or windows) 

 

To light the burners: 
- open the gas cylinder valve and the corresponding valve (applicable when the 
caravan is equipped with more than one gas-consuming appliance) in the kitchen 
cupboard, 

light the lighter and bring it close to the burner holes, 

-  turn  the  valve  knob  of  the  selected  burner  from  the  "closed"  position 
counterclockwise to the low or high flame position, press and hold the knob until 
the gas ignites. 

To extinguish the flame, turn the knob to the "closed" 

position. 

When not using the stove, the gas cylinder valve should be

unscrew the heating valve located in the kitchen cupboard, 

- turn the knob on the appliance (the gas in the appliance ignites 
automatically). 

When not using the heater, the valve in the kitchen cupboard that 

supplies gas to the appliance should be closed. 

A detailed description of the operation, use and technical data of the 

heater can be found in the supplementary manual (additional equipment). 

 

 

SEATING AND SLEEPING AREA 

 

To create a seating area: 
-  attach the table hooks (mounted at the edge of the table) to the aluminium 

slat (2) located on the caravan wall, 

-  unfold the table leg (4) by pushing the button (3), 
-  press down the buttons (1) of the table hooks. 

To create a sleeping area: 

- press down the buttons (1) of the table hooks, 
- fold the table leg (4) by pushing the button (3), 
- remove the table from the aluminium slat (2) and place it on the slat (6) while 

laying the table on the bed edges (5). 

closed. 

1

 

 

NOTE ! 
The stove must be used in accordance with the information 

contained in the stove manual which is supplied with the caravan. 
It is prohibited to connect the stove directy to the cylinder without a 
suitable reducer. 
 
 

-15- 

 
 
 
 
 

 
 
 

-16- 

Summary of Contents for N126n

Page 1: ...ARAVAN OPERATION 9 HITCHING 9 LOADING 10 BEFORE DRIVING 10 DRIVING 11 UNHITCHING 11 5 OPERATION SERVICE CHASSIS MAINTENANCE 12 GENERAL INFORMATION 12 BALL COUPLING 12 SUSPENSION 12 5 4 WHEELS 12 BRAKI...

Page 2: ...otal width 2050 mm Total height 2550 mm Bodywork length 3050 mm Interior bodywork width 1960 mm Interior bodywork height 1815 mm Wheel track 1500 mm Kerb weight N126n N126nt N126nn N126nl N126ntl 660...

Page 3: ...pcs 6 Gas stove 1 pc 7 Sink 1 pc 8 230V connection cable with a length of 25 lin m 1 pc 9 Electric water pump 1 pc 10 Caravan instruction manual 1 pc 11 Gas stove manual 1 pc 12 Cooler manual 1 pc IN...

Page 4: ...e 2 2 sink 3 front sofa 4 long table 5 bathroom 6 wardrobe 7 hanging cupboards 8 side closet 9 sleeping spot of 130x193 cm a b Fig 3 Day layout a and night layout b of the N126nn caravan 1 gas stove 2...

Page 5: ...3 front sofa 4 long table 5 back sofa 7 hanging cupboards 8 side closet 9 sleeping spot of 130x193 cm a b Fig 5 Day layout a and night layout b of the N126ntl caravan 1 gas stove 2 sink 3 front sofa 4...

Page 6: ...50 420 mm from the ground when the vehicle is loaded to its permissible total weight LOADING When loading make sure that the load is evenly distributed in the caravan and applies appropriate pressure...

Page 7: ...S MAINTENANCE GENERAL INFORMATION It is necessary to regularly check the screw connections BALL COUPLING Depending on their type caravans made by Niewiad w sp z o o can be equipped with ball couplings...

Page 8: ...The parking brake is only effective when the ratchet lever is on the last tooth Insufficient engagement of the lever causes the caravan to brake forwards without providing adequate braking in the rea...

Page 9: ...itchen cupboard light the lighter and bring it close to the burner holes turn the valve knob of the selected burner from the closed position counterclockwise to the low or high flame position press an...

Page 10: ...unqualified persons to modify electrical systems and equipment 230V and 12V GAS SYSTEM connect the caravan to an external 230V power supply using an extension cord plug the power supply unit into the...

Page 11: ...nts the valve and the connection between the valve and the reducer with soapy water or spray it with a soapy substance and then open the valve The absence of expanding gas bubbles indicates that the s...

Page 12: ...nt caravan is optionally equipped with a travel toilet The toilet is fitted with a tank accessed from the outside of the caravan through a special door A detailed description of the operation and use...

Page 13: ...rake system inspection adjustment and lubrication Wheel bearing adjustment inspection Lubrication of the bearing sleeves of the overrun device Change of grease in the cone bearings of wheels whichever...

Reviews: