272
APPENDIX: Standard Programs
8.8
Standard Programs
The RT-5100 has five programs of A, B, C, D and E, which can be programmed by the user.
The following standard programs have already been written in Programs A and B as factory setting.
Program A: Precision course 1
The final prescription is obtained after the monocular full correction (subjective data) is stored. The
binocular balance test and auto adjustment are performed in the final field. Then the precise addition
power is measured with the cross grid for near point in the subjective field.
(R: right eye, L: left eye, B: binocular eye)
1. AR data entry
Enter the AR data.
<Unaided field>
2. Unaided VA test
Measure the unaided VA.
<Aided field>
3. LM data entry
Enter the LM data.
4. Aided VA entry
Measure the aided VA.
<Subjective field>
5. R: AR data check
Check that the VA is about 20/30 in the AR data.
6. R: Red-green test
Spherical refinement with the red-green chart (fog + 0.5)
7. R: Cross cylinder test (axis)
Measure the cylindrical axis with the cross cylinder lens.
8. R: Cross cylinder test (power)
Measure the cylindrical power with the cross cylinder lens.
9. R: Red-green test
Spherical refinement with the red-green chart (fog + 0.5)
10. R: Best possible VA check (monocular full correction)
Best possible VA on the chart with the most plus power
11. L: AR data check
Check that the VA is about 20/30 in the AR data.
12. L: Red-green test
Spherical refinement with the red-green chart (fog + 0.5)
13. L: Cross cylinder test (axis)
Measure the cylindrical axis with the cross cylinder lens.
14. L: Cross cylinder test (power)
Measure the cylindrical power with the cross cylinder lens.
15. L: Red-green test
Spherical refinement with the red-green chart (fog + 0.5)
16. L: Best possible VA check (monocular full correction)
Best possible VA on the chart with the most plus power
<Final field>
17. B: Binocular balance test
Test the binocular balance.
18. B: Stereo test
Check the steroscopic vision and enter the stereoparallax
19. B: Power adjustment (auto)
Power adjustment depending on the purpose (auto adjustment)
161221687130 承認済
Uncontrolled copy when printed.
Summary of Contents for RT-5100
Page 12: ...X 161221687130 承認済 Uncontrolled copy when printed ...
Page 18: ... XVI 161221687130 承認済 Uncontrolled copy when printed ...
Page 46: ...28 BEFORE USE Getting Started and Exiting 161221687130 承認済 Uncontrolled copy when printed ...
Page 274: ...256 MAINTENANCE List of Replacement Parts 161221687130 承認済 Uncontrolled copy when printed ...
Page 302: ...284 EMC ELECTROMAGNETIC COMPATIBILITY 161221687130 承認済 Uncontrolled copy when printed ...