17
4.4.2 PHA mode setting (EXT)
Delay emission can be set within the input signal range between 27 and 3300 [fpm].
In the PHA mode, the phase from the external trigger pulse entry to strobe flash emission can be changed by 1° using the dial
within the range between 1° and 359°.
Press “UNIT” to toggle between PHA mode (DEG) and PHA mode (ms).
The phase can be changed by 0.01 [ms] within the range between 0.00 and 999.99 [ms], by 0.1 [ms] within the range between
1000.0 and 2216.0 [ms].
A time longer than the light emission cycle cannot be set. (PHA mode ms)
Press “MODE” in PHA mode to switch to FPM mode.
Operation
Display
Increase / decrease
Delay angle / time
Press “UNIT” to toggle
between DEG and ms
Press “MODE” to
switch to FPM mode
Decrease delay angle
Increase delay angle
CCW
CW
CCW
CW
PHA mode
FPM mode
Decrease delay angle
Increase delay angle
Summary of Contents for DT-3015P
Page 36: ...35 5 2Externaldimensions...
Page 38: ......
Page 39: ......
Page 40: ...Address 1 Terada Kohtari Nagaokakyo city Kyoto 617 0833 Japan Phone 81 75 958 3621...