128
SM-Applications Modules & Motion Processors User Guide
Issue Number: 4
80
Inter-Option module comms error with module unknown
slot.
Yes
Yes
Yes
81
•
Slot selected as the reference or feedback does not
contain a position option module
•
Attempt to change the Reference source or the
Feedback source in more than one task.
APC internal error. See parameter
#81.38
. This may be
caused by one of the following:
•
CAM table too small
•
A change of too many CAM segments has occurred
at the CAM table input
•
CAM is selected but size is zero
•
CAM absolute mode selected and Reset Index or
Reset Position in segment is out of range
May
Yes
Yes
82
Communcations to drive faulty.
May
Yes
Yes
Table 13-6 Terminals
Terminal
Function
Description
1
0V SC
0V connection for EIA-RS485 port
2
/RX
EIA-RS485 Receive line (negative). Incoming.
3
RX
EIA-RS485 Receive line (positive). Incoming.
4
/TX
EIA-RS485 Transmit line (negative). Outgoing.
5
TX
EIA-RS485 Transmit line (positive). Outgoing.
6
CTNet A
CTNet data line
7
CTNet Shield Shield connection for CTNet
8
CTNet B
CTNet data line
9
0V
0V connection for digital I/O
10
DIGIN0
Digital input 0
11
DIGIN1
Digital input 1
12
DIGOUT0
Digital output 0
13
DIGOUT1
Digital output 1
Table 13-5 Second Processor Error Codes (Continued)
Error
Code
Reason
Trip
Drive?
ERROR
task?
Prog
Halted?