Table 6-8 Open loop and RFC-A maximum permissible continuous output current @ 50 °C (122 °F) ambient (cooling fan at middle speed)
6.1.3 Continuous rating
Table 6-9 Continuous rating with no overload @ 0 Hz output frequency, 40 °C (104 °F) ambient
Model
Heavy Duty
Maximum permissible continuous output current (A) (Pr 06.045 = 7 or -7)
2 kHz
3 kHz
4 kHz
6 kHz
8 kHz
12 kHz
16 kHz
200 V
01200022
2.2
2.2
2.2
2.2
2.2
2.2
2.2
01200040
4.0
4.0
4.0
4.0
4.0
4.0
4.0
01200065
6.5
6.5
6.5
6.5
6.2
5.5
4.7
02200090
8.9
8.6
8.4
8.0
7.8
7.6
7.6
02200120
8.9
8.6
8.4
8.0
7.8
7.6
7.6
03200160
16.0
15.8
15.2
13.8
12.6
11.6
10.4
400 V
01400015
1.5
1.5
1.5
1.5
1.5
1.5
1.5
01400030
3.0
3.0
2.9
2.7
2.5
2.3
1.8
01400042
3.2
3.1
2.9
2.7
2.5
2.3
1.8
02400060
6.0
6.0
6.0
6.0
6.0
5.5
4.8
02400080
8.0
7.7
7.2
6.7
6.2
5.5
4.8
02400105
8.1
7.7
7.2
6.7
6.2
5.5
4.8
03400135
13.5
13.3
12.6
10.9
9.6
7.5
6.1
03400160
13.8
13.3
12.6
10.9
9.6
7.5
6.1
Model
Heavy Duty
Nominal rating
Maximum permissible continuous output current (A) at 0 Hz with no overload
kW
hp
2 kHz
3 kHz
4 kHz
6 kHz
8 kHz
12 kHz
16 kHz
200 V
01200022
0.37
0.5
2.2
2.2
2.2
01200040
0.75
1.0
4.0
4.0
4.0
01200065
1.1
1.5
6.5
6.5
6.5
02200090
2.2
2.0
9.0
9.0
9.0
02200120
2.2
3.0
12.0
11.6
10.8
03200160
4.0
5.0
16.0
16.0
16.0
400 V
01400015
0.37
0.75
1.5
1.5
1.5
01400030
0.75
1.5
3.0
3.0
3.0
01400042
1.5
2.0
4.2
4.2
4.2
02400060
2.2
3.0
6.0
6.0
6.0
02400080
3.0
5.0
8.0
8.0
6.9
02400105
4.0
5.0
10.5
9.4
6.9
03400135
5.5
7.5
13.5
11.5
9.3
03400160
5.5
10.0
16.0
15.8
13.8
11.5
9.3
Summary of Contents for Digitax HD M75 Series