Digitax HD M75X Series Installation and Technical Guide
101
Issue Number: 5
Table 6-4 Open loop and RFC-A maximum permissible continuous output current @ 40 °C (104 °F) ambient with rear duct fitted
Table 6-5 Open loop and RFC-A maximum permissible continuous output current @ 40 °C (104 °F) ambient (cooling fan at middle speed)
Model
Heavy Duty
Nominal rating
Maximum permissible continuous output current (A) allowing for 175 % overload for
4.5 s with rear duct fitted
kW
hp
2 kHz
3 kHz
4 kHz
6 kHz
8 kHz
12 kHz
16 kHz
200 V
01200022
0.37
0.5
2.2
2.2
2.2
01200040
0.75
1.0
4.0
4.0
4.0
01200065
1.1
1.5
6.5
6.1
5.5
02200090
2.2
2.0
9.0
9.0
9.0
02200120
2.2
3.0
12.0
11.9
11.4
03200160
4.0
5.0
16.0
16.0
15.4
400 V
01400015
0.37
0.75
1.5
1.5
1.5
01400030
0.75
1.5
3.0
3.0
2.9
01400042
1.5
2.0
4.1
4.0
3.8
3.6
3.4
3.4
2.9
02400060
2.2
3.0
6.0
6.0
6.0
02400080
3.0
5.0
8.0
8.0
6.7
02400105
4.0
5.0
10.5
9.6
8.0
6.7
03400135
5.5
7.5
13.5
11.5
9.6
03400160
5.5
10.0
16.0
15.4
14.1
11.5
9.6
Model
Heavy Duty
Nominal rating
Maximum permissible continuous output current (A) (Pr 06.045 = 7 or -7)
kW
hp
2 kHz
3 kHz
4 kHz
6 kHz
8 kHz
12 kHz
16 kHz
200 V
01200022
0.37
0.5
2.2
2.2
2.2
01200040
0.75
1.0
4.0
4.0
4.0
01200065
1.1
1.5
6.5
6.5
6.4
02200090
2.2
2.0
9.0
9.0
9.0
02200120
2.2
3.0
12.0
11.5
11.1
11.1
03200160
4.0
5.0
16.0
15
14.6
400 V
01400015
0.37
0.75
1.5
1.5
1.5
01400030
0.75
1.5
3.0
3.0
2.5
01400042
1.5
2.0
4.2
3.2
2.5
02400060
2.2
3.0
6.0
6.0
6.0
02400080
3.0
5.0
8.0
7.5
6.6
02400105
4.0
5.0
10.5
10.4
9.9
9.0
8.4
7.5
6.6
03400135
5.5
7.5
13.5
12.6
10.1
8.0
03400160
5.5
10.0
16.0
15.7
14.4
12.6
10.1
8.0