2. Gently position wires in wall box, attach sensor switch to the box.

DESCRIPTION

-01-

 

-

3

0

-

-

2

0

-

 

OCCUPANCY SENSOR,

VACANCY SENSOR

 WALL SWITCH

SPECIFICATIONS

Neutral

White

Hot

Black

Ground

Green

Load

Red

LOAD

Figure 2

 

INSTALLATION:

Figure 3

OS150B, VS150

OS150B / VS150

Neutral(White)

INSTALLATION INSTRUCTIONS

Voltage ............................................................……  120VAC,60Hz     

 Incandescent .......................................................................  500W

Motor  .............................................................................…1/8Hp        

Time Delay  .....................................................…  15Sec to 30Mins  

Fluorescent..............................….....................................…500VA

OS150B

 Turn off the circuit breaker before installation.

WARNING:

Do not exceed electrical ratings.

Indoor use only.

Line(Hot), Red lead to Load wire, White lead to Neutral wire, Green 

1. Connect lead wires as WIRING DIAGRAM (see Figure 2): Black lead to 

lead to Ground.

Wiring Diagram:

3.  Mount device “TOP” up.
4.  Restore power at circuit breaker or fuse, wait

6.  Locate the adjustment knobs on the control panel to perform test 

5.  Remove the small cover plate (Illustrated in Figure 3).

7. Replace the small cover plate after testing and adjustment.
8. Attach the wallplate.

and adjustment (Illustrated in Figure 3).

 one minute.

ADJUSTMENT

Default position: 15 Seconds (Test mode)
Adjustable: from 15 Seconds to

Time Delay knob

30 Minutes (clockwise)

Default position: Center at 65%
Adjustable: 30% (Position 1) to 100% 

Note: Turn toward right for greater room space.

Turn toward left to avoid false alert in smaller room and near 

the doorway or heat source.  

Default position: Daylight (100% at position 4)

Adjustable: Daylight to 30Lux (Counter clockwise) 

Note: avoid wasting energy by turning on the light under daylight.

Sensor Sensitivity Range Knob

Ambient Light Level Knob

Figure 4

(Position 4)

OPERATION

The passive infrared sensors work by detecting the difference between
 heat emitted from the human body in motion and the background space.
The sensor switch can turn a load on and hold it as long as the sensor
detects occupancy. After no motion is detected for the set time delay, the 

As illustrated in Figure 5, the Load stays Off when the button is
pushed in and locked. (switched Off)

Push-button for OS150B

VS150

       

  Light Level................................................................  30 Lux--Daylight

Operation Temperature....................................................... 32 F--131 F

load turns off automatically.The sensor switch has one relay ( equal
 to single pole switch), and also includes a Ambient Light Level Sensor. 

The coverage range of the sensor switch is specified and illustrated 

the light to turn off even though someone is still in the detection area.

in Figure 1. Large objects and some transparent barriers like glass 
windows will obstruct the sensors' view and prevent detection, causing

Coverage Area

As illustrated in Figure 6, the Load turns On after the button is

Press

OFF

Figure 5

Press and release

AUTO

Figure 6

(Lock)

pressed and released.The sensor switch stays at the OCC Mode
until the button is pressed Off next time.

Best: 260 sq.ft.

Regular:650 sq.ft.

Maximum: 980 sq.ft.

18'

18'

Top View

9'

9'

15'

30'

5'

4'

Side View

150

Figure 1

VS150

By Pushing in the button, the Load can be turned On/Off as illustrated 

Manual On/Off Button

Turning On  

Manually turn On the Load by pushing the button whenever the Load is Off.

Turning Off 

Manually turn Off the Load by pushing the button . Without pushing 

Turning On Automatically

Only after the Load automatically turns Off, the Load can be turned On
automatically if occupancy detected within 30 seconds.

in Figure 5.

the button, the Load is to be turned Off after set time delay.